Suppr超能文献

基于千伏投影流与数字重建射线图像实时配准的肝脏肿瘤屏气立体定向体部放疗期间分次内膈肌变化:一例报告

Intrafractional Diaphragm Variations During Breath-Hold Stereotactic Body Radiotherapy for a Liver Tumor Based on Real-Time Registration Between Kilovoltage Projection Streaming and Digitally Reconstructed Radiograph Images: A Case Report.

作者信息

Katano Atsuto, Nozawa Yuki, Minamitani Masanari, Ohira Shingo, Nakagawa Keiichi

机构信息

Radiology, The University of Tokyo Hospital, Tokyo, JPN.

Comprehensive Radiation Oncology, The University of Tokyo, Tokyo, JPN.

出版信息

Cureus. 2023 Nov 2;15(11):e48188. doi: 10.7759/cureus.48188. eCollection 2023 Nov.

Abstract

In liver stereotactic body radiotherapy (SBRT), precise image guidance is paramount, serving as the foundation of this treatment approach. The accuracy of SBRT in liver cancer treatment heavily relies on meticulous imaging techniques. The diaphragm, situated adjacent to the liver, is a crucial anatomical structure susceptible to positional and motion variations, which can potentially impact the accuracy of liver tumor targeting. This study explores the application of real-time kilovoltage projection streaming images (KVPSI) in comparison to digitally reconstructed radiography (DRR) for assessing diaphragm position deviations during breath-hold liver tumor SBRT. A 76-year-old male diagnosed with cholangiocarcinoma underwent breath-hold SBRT using split arc volumetric modulated arc therapy (VMAT), where a full arc was split into six sub-arcs, each spanning 60 degrees. The diaphragm dome positions were continuously monitored through KVPSI during treatment. The intrafractional position deviations of the diaphragm were calculated and analyzed for each split arc. The case report revealed a mean diaphragm dome deviation of 0.47 mm (standard deviation: 4.47 mm) in the entire arc. This pioneering study showcases the feasibility of intrafractional diaphragm position variation assessment using real-time KVPSI during the breath-hold liver tumor VMAT-SBRT. Integrating real-time imaging techniques enhances our comprehension of the intra-breath-hold variations, thereby guiding adaptive treatment strategies and potentially improving treatment outcomes. Clinical validation through further research is essential.

摘要

在肝脏立体定向体部放射治疗(SBRT)中,精确的图像引导至关重要,是这种治疗方法的基础。SBRT在肝癌治疗中的准确性严重依赖于精细的成像技术。与肝脏相邻的膈肌是一个关键的解剖结构,容易出现位置和运动变化,这可能会影响肝脏肿瘤靶向的准确性。本研究探讨了实时千伏投影流图像(KVPSI)与数字重建X线摄影(DRR)相比,在评估屏气肝脏肿瘤SBRT期间膈肌位置偏差方面的应用。一名76岁被诊断为胆管癌的男性患者接受了屏气SBRT,采用了分割弧容积调强弧形放疗(VMAT),其中一个全弧被分割为六个子弧,每个子弧跨度为60度。在治疗过程中通过KVPSI持续监测膈肌穹窿位置。计算并分析每个分割弧的膈肌分次内位置偏差。该病例报告显示,整个弧中膈肌穹窿的平均偏差为0.47毫米(标准差:4.47毫米)。这项开创性研究展示了在屏气肝脏肿瘤VMAT-SBRT期间使用实时KVPSI评估膈肌分次内位置变化的可行性。整合实时成像技术可增强我们对屏气内变化的理解,从而指导适应性治疗策略并可能改善治疗效果。通过进一步研究进行临床验证至关重要。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/06f8/10695080/f770d87d4f9d/cureus-0015-00000048188-i01.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验