Suppr超能文献

-Endo-Z 锉或 Bladesonic 超声工作尖对充填材料适应性的影响:一项 micro-CT 研究。

Effect of Endo-Z bur or Bladesonic ultrasonic tip on the adaptation of filling material. A micro-CT study.

机构信息

Department of Restorative Dentistry, School of Dentistry, UNESP - Universidade Estadual Paulista, Araraquara, SP, Brazil.

Departament of Dentistry - Centro Universitário Presidente Antônio Carlos - UNIPAC, Barbacena, MG, Brazil and Department of Dentistry - Centro Universitário Presidente Tancredo de Almeida Neves - UNIPTAN, São João del Rei, MG, Brazil.

出版信息

Braz Dent J. 2023 Dec 22;34(5):29-35. doi: 10.1590/0103-6440202305474. eCollection 2023.

Abstract

This study aimed to evaluate the effect of apicoectomy performed with a bur or an ultrasonic tip on the adaptation of the filling material to root canal dentin. Twenty human mandibular incisors were selected and prepared with a ProDesign Logic system up to diameter 40/.05. The root canals were filled with Bio-C Sealer (Angelus, PR, Brazil) using the single cone technique and were stored at 37ºC and 95% relative humidity for 7 days. After this period, the apicoectomy of the 3 millimeters of the root apex was performed using Endo-Z bur (Dentsply Sirona) or Bladesonic ultrasonic tip (Helse Ultrasonic, Santa Rosa de Viterbo, Brazil) (n=10). The specimens were scanned by micro-computed tomography (micro-CT; SkyScan 1176) with a voxel size of 8.74 µm after obturation and after apicoectomy. The percentage of voids at the interface between the filling material and the root canal wall was evaluated in the apical 4 mm of the root after apicoectomy, besides the time cutting to both devices. The data obtained were submitted to paired and unpaired t-tests (α = 0.05). Endo-Z and Bladesonic increased the percentage of voids between the filling material and the dentin after apicectomy (p<0.05), and they were similar (p>0.05). Endo-Z has a shorter time to perform apicoectomy compared to Bladesonic (p<0.05). Apicectomies with Endo-Z or Bladesonic could harm the material/dentin interface, while the Endo-Z bur was faster than the Bladesonic ultrasonic tip.

摘要

本研究旨在评估使用车针对或超声尖端进行根尖切除术对填充材料与根管牙本质适应性的影响。选择 20 个人类下颌切牙,用 ProDesign Logic 系统预备至直径 40/.05。使用单锥技术用 Bio-C Sealer(Angelus,PR,巴西)填充根管,并在 37°C 和 95%相对湿度下储存 7 天。在此期间,使用 Endo-Z 车针(登士柏西诺德)或 Bladesonic 超声尖端(Helse Ultrasonic,Santa Rosa de Viterbo,巴西)对根尖 3 毫米进行根尖切除术(n=10)。在充填入根管后和根尖切除后,使用 micro-CT(SkyScan 1176)对样本进行扫描,体素大小为 8.74 µm。在根尖切除后对根尖 4 毫米的根管壁和填充材料之间的界面空隙率进行评估,同时评估两种器械的切割时间。将获得的数据进行配对和非配对 t 检验(α=0.05)。Endo-Z 和 Bladesonic 增加了根尖切除后填充材料与牙本质之间的空隙率(p<0.05),且两种器械之间无差异(p>0.05)。与 Bladesonic 相比,Endo-Z 进行根尖切除术的时间更短(p<0.05)。使用 Endo-Z 或 Bladesonic 进行根尖切除术可能会损害材料/牙本质界面,而 Endo-Z 车针比 Bladesonic 超声尖端更快。