Kim Minchan, Yoon Kicheol, Lee Sangyun, Shin Mi-Seung, Kim Kwang Gi
Medical Devices R&D Center, Gachon University Gil Medical Center, 21, 774 Beon-gil, Namdong-daero, Namdong-gu, Incheon 21565, Republic of Korea.
Premedicine Course, College of Medicine, Gachon University, 38-13, 3 Beon-gil, Dokjom-ro 3, Namdong-gu, Incheon 21565, Republic of Korea.
Diagnostics (Basel). 2024 Feb 4;14(3):335. doi: 10.3390/diagnostics14030335.
For ultrasound diagnosis, a gel is applied to the skin. Ultrasound gel serves to block air exposure and match impedance between the skin and the probe, enhancing imaging efficiency. However, if use of the ultrasound gel exceeds a certain period of time, it may dry out and be exposed to air, causing impedance mismatch and reducing imaging resolution. In such cases, the use of a soft, solid gel proves advantageous, as it can be employed for an extended period without succumbing to the drying phenomenon and can be reused after disinfection. Its soft consistency ensures excellent skin adhesion. Our soft solid gel demonstrated approximately 1.2 times better performance than water, silicone, and traditional ultrasound gels. When comparing the dimensions of grayscale, dead zone, vertical, and horizontal regions, the measurements for the traditional ultrasound gel were 93.79 mm, 45.32 mm, 103.13 mm, 83.86 mm, and 83.86 mm, respectively. In contrast, the proposed soft solid gel exhibited dimensions of 105.64 mm, 34.48 mm, 141.1 mm, and 102.8 mm.
在超声诊断中,需在皮肤上涂抹凝胶。超声凝胶用于防止空气接触,并使皮肤与探头之间的阻抗相匹配,从而提高成像效率。然而,如果超声凝胶的使用时间超过一定时长,它可能会变干并暴露于空气中,导致阻抗失配,降低成像分辨率。在这种情况下,使用柔软的固体凝胶则具有优势,因为它可以长时间使用而不会出现变干现象,并且消毒后可重复使用。其柔软的质地确保了与皮肤的良好贴合性。我们的柔软固体凝胶表现出比水、硅酮和传统超声凝胶约好1.2倍的性能。在比较灰度、盲区、垂直和水平区域的尺寸时,传统超声凝胶的测量值分别为93.79毫米、45.32毫米、103.13毫米、83.86毫米和83.86毫米。相比之下,所提出的柔软固体凝胶的尺寸为105.64毫米、34.48毫米、141.1毫米和102.8毫米。