Suppr超能文献

猪双心室压力-容积环的技术与分析方法,包括完全血管内、经皮闭胸大型动物模型。

Technical and analytical approach to biventricular pressure-volume loops in swine including a completely endovascular, percutaneous closed-chest large animal model.

作者信息

Stonko David P, Rousseau Mathieu C, Price Colin, Benike Amy, Treffalls Rebecca N, Brunton Nichole E, Rosen Dorian, Morrison Jonathan J

机构信息

Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, The Johns Hopkins Hospital, Baltimore, MD.

Division of Vascular and Endovascular Surgery, Mayo Clinic, Rochester, MN.

出版信息

JVS Vasc Sci. 2024 Jan 17;5:100190. doi: 10.1016/j.jvssci.2024.100190. eCollection 2024.

Abstract

Pressure-volume (PV) loop analysis is a sophisticated invasive approach to quantifying load-dependent and independent measures of cardiac function. Biventricular (BV) PV loops allow left and right ventricular function to be quantified simultaneously and independently, which is important for conditions and certain physiologic states, such as ventricular decoupling or acute physiologic changes. BV PV loops can be performed in an entirely endovascular, percutaneous, and closed-chest setting. This technique is helpful in a survival animal model, as a percutaneous monitoring system during endovascular device experiments, or in cases where chest wall compliance is being tested or may be a confounder. In this article, we describe the end-to-end implementation of a completely endovascular, totally percutaneous, and closed-chest large animal model to obtain contemporaneous BV PV loops in 40 to 70 kg swine. We describe the associated surgical and technical challenges and our solutions to obtaining endovascular BV PV loops, closed-chest cardiac output, and stroke volume (including validation of the correction factor necessary for thermodilution), as well as how to perform endovascular inferior vena cava occlusion in this swine model. We also include techniques for data acquisition and analysis that are required for this method.

摘要

压力-容积(PV)环分析是一种复杂的侵入性方法,用于量化心脏功能的负荷依赖性和独立性指标。双心室(BV)PV环可同时独立地量化左心室和右心室功能,这对于诸如心室解耦或急性生理变化等情况和特定生理状态很重要。BV PV环可在完全血管内、经皮和闭胸的情况下进行。该技术在生存动物模型中很有用,可作为血管内装置实验期间的经皮监测系统,或用于测试胸壁顺应性或可能成为混淆因素的情况。在本文中,我们描述了一种完全血管内、完全经皮和闭胸的大型动物模型的端到端实施,以在40至70千克的猪中获得同期的BV PV环。我们描述了相关的手术和技术挑战以及我们获得血管内BV PV环、闭胸心输出量和每搏输出量(包括热稀释所需校正因子的验证)的解决方案,以及如何在该猪模型中进行血管内下腔静脉闭塞。我们还包括该方法所需的数据采集和分析技术。