Suppr超能文献

全口种植体印模的校准口内扫描方案(CISP):与传统印模、口内扫描和带扫描辅助装置的口内扫描的体外比较。

Calibrated intraoral scan protocol (CISP) for full-arch implant impressions: An in vitro comparison to conventional impression, intraoral scan, and intraoral scan with scan-aid.

机构信息

Department of Biologic and Materials Sciences, Division of Prosthodontics, School of Dentistry, University of Michigan, Ann Arbor, Michigan, USA.

Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Michigan, USA.

出版信息

Clin Implant Dent Relat Res. 2024 Oct;26(5):879-888. doi: 10.1111/cid.13338. Epub 2024 May 15.

Abstract

OBJECTIVE

To assess a newly developed intraoral scan protocol in enhancing the accuracy of complete-arch implant impressions.

MATERIALS AND METHODS

Four impression approaches were applied to the same maxillary edentulous model with 6 implants: (1) intraoral scan (IOS), (2) intraoral scan with scan aid (IOS-SA), (3) calibrated intraoral scan protocol (CISP), and (4) conventional splinted open-tray impression (CONV). Each approach was repeated 10 times, and a direct scan of the model with a desktop scanner was used as a reference model. The alignment of scans and the reference model was conducted by two methods: (a) aligning all scan bodies to evaluate the overall fit, and (b) aligning the first and second scan bodies to simulate the Sheffield fit test for passive fitting of multiple implant-supported prostheses. Linear deviations from the reference model (trueness) and within each group (precision) were analyzed using Python scripts.

RESULTS

When aligned by all scan bodies, the CISP group exhibited comparable mean trueness (38.33 μm) and precision (45.97 μm) to the CONV group (44.30 and 47.92 μm respectively), both of which significantly outperformed the IOS group (86.82 and 83.17 μm, respectively). Furthermore, in the virtual Sheffield fit test, the CISP group achieved the highest levels of mean trueness at the end span (121.7 μm), making a linear deviation reduction of 36.7%, 60%, and 41.4% when compared to the CONV, the IOS, and the IOS-SA groups, respectively. Moreover, the CISP group (104.3 μm) displayed a remarkable 65, 182, and 86 μm advantage in precision over the CONV, IOS, and IOS-SA groups, respectively.

CONCLUSION

CISP demonstrated comparable accuracy to the gold standard, the conventional splinted open-tray impression. Furthermore, it excelled in the virtual passive fitting test.

摘要

目的

评估一种新的口腔内扫描方案在提高全口种植体印模准确性方面的效果。

材料与方法

将四种印模方法应用于同一个上颌无牙模型,模型上有 6 个种植体:(1)口内扫描(IOS),(2)口内扫描加扫描辅助(IOS-SA),(3)校准口内扫描方案(CISP),(4)传统分牙托盘开放式印模(CONV)。每种方法重复 10 次,并使用桌面扫描仪对模型进行直接扫描作为参考模型。通过两种方法对扫描和参考模型进行配准:(a)对齐所有扫描体以评估整体拟合度,(b)对齐第一和第二扫描体以模拟 Sheffield 拟合测试,用于被动拟合多个种植体支持的修复体。使用 Python 脚本分析参考模型的线性偏差(准确性)和每个组内的偏差(精密度)。

结果

当通过所有扫描体对齐时,CISP 组的平均准确性(38.33μm)和精密度(45.97μm)与 CONV 组(分别为 44.30μm 和 47.92μm)相当,均显著优于 IOS 组(分别为 86.82μm 和 83.17μm)。此外,在虚拟 Sheffield 拟合测试中,CISP 组在末端跨度达到最高的平均准确性(121.7μm),与 CONV、IOS 和 IOS-SA 组相比,线性偏差分别减少了 36.7%、60%和 41.4%。此外,CISP 组在精密度方面与 CONV、IOS 和 IOS-SA 组相比,分别具有显著的 65μm、182μm 和 86μm 的优势。

结论

CISP 与金标准(传统分牙托盘开放式印模)具有相当的准确性,并且在虚拟被动拟合测试中表现出色。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验