Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Alanya Alaaddin Keykubat University, Antalya, Turkey.
Department of Endodontics, Faculty of Dentistry, Erciyes University, Melikgazi, Kayseri, 38039, Turkey.
Clin Oral Investig. 2024 Jun 25;28(7):394. doi: 10.1007/s00784-024-05773-5.
The study aims to compare the detection of the middle mesial canal (MMC) in mandibular molar teeth using cone beam computed tomography (CBCT) with different voxel sizes when the mesiobuccal (MB) and mesiolingual (ML) canals have three distinct phases (unpreparation, preparation and obturation and the removal of the obturation and repreparation).
Two hundred forty-two extracted human mandibular molars were collected and kept in a physiological saline solution prior to use. 0.2-, 0.28- and 0.35-mm voxel sizes CBCT (n = 242) were performed in three phases (Ph): Ph1, no MB and ML canal preparation or obturation; Ph2, after MB and ML canals preparation and obturation; and Ph3, after the removal of the obturation of MB and ML canals and canals repreparation. Images were analyzed using OnDemand3D® software. After the CBCT acquisition in Ph3, all the samples were clarified to visualize the presence of the MMC directly. A blinded, previously calibrated examiner analyzed all the images.
The MMC was detected in 15 of the 242 teeth after the clearing technique. The lowest MMC detection rate was observed at 0.35-mm voxel size regardless of the ML and MB canal condition, while the highest was observed at 0.2-mm voxel size (P < 0.05). There is no statistically significant difference between 0.2-mm and 0.28-mm voxel sizes (P > 0.05). In all voxel sizes, the highest rate of detectability of the MMC was seen in Phase 1, while the lowest was in Phase 2.
It may be appropriate to take a 0.20-mm voxel size CBCT image, especially after the removal of root canal filling.
An appropriate CBCT voxel size and the absence of root canal filling in the root canal system help to detect the missing MMC.
本研究旨在比较不同体素大小的锥形束 CT(CBCT)在下颌磨牙 MB 和 ML 根管有三个不同阶段(未预备、预备和充填及去除充填和再预备)时对中颊根管(MMC)的检测。
收集 242 颗离体下颌磨牙,在使用前置于生理盐水中。在三个阶段(Ph)进行 0.2、0.28 和 0.35-mm 体素大小 CBCT(n=242):Ph1,无 MB 和 ML 根管预备或充填;Ph2,MB 和 ML 根管预备和充填后;Ph3,MB 和 ML 根管的充填物去除和根管再预备后。使用 OnDemand3D®软件分析图像。在 Ph3 进行 CBCT 采集后,所有样本均进行澄清以直接观察 MMC 的存在。一位经过盲法和校准的检查者分析了所有图像。
在 242 颗牙齿中,有 15 颗牙齿在经过澄清技术后检测到 MMC。无论 ML 和 MB 根管的情况如何,体素尺寸为 0.35-mm 时的 MMC 检测率最低,而体素尺寸为 0.2-mm 时的检测率最高(P<0.05)。0.2-mm 和 0.28-mm 体素尺寸之间没有统计学上的显著差异(P>0.05)。在所有体素尺寸中,MMC 的检测率在 Ph1 时最高,在 Ph2 时最低。
在根管系统中去除根管充填物后,可能适合拍摄 0.20-mm 体素大小的 CBCT 图像。
适当的 CBCT 体素大小和根管系统中无根管充填有助于检测缺失的 MMC。