Department of Clinical Pharmacy, College of Pharmacy, University of Michigan, Ann Arbor, MI, USA.
Pharmacokinetic & Mass Spectrometry Core, College of Pharmacy, University of Michigan, Ann Arbor, MI, USA.
Br J Clin Pharmacol. 2024 Nov;90(11):2897-2909. doi: 10.1111/bcp.16182. Epub 2024 Jul 25.
Dried blood volumetric absorptive microsamples (VAMS) may facilitate home-based sampling to enhance therapeutic drug monitoring after transplantation. This study aimed to clinically validate a liquid chromatography-tandem mass spectrometry assay using 2 VAMS devices with different sampling locations (Tasso-M20 for the upper arm and Mitra for the finger). Patient preferences were also evaluated.
Clinical validation was performed for tacrolimus and mycophenolic acid by comparison of paired VAMS and venipuncture samples using Passing-Bablok regression and Bland-Altman analysis. Conversion of mycophenolic acid VAMS to serum concentrations was evaluated using haematocrit-dependent formulas and fixed correction factors defined a priori. Patients' perspectives, including useability, acceptability and feasibility, were also investigated using established questionnaires.
Paired samples (n = 50) were collected from 25 kidney transplant recipients. Differences for tacrolimus whole-blood concentration were within ±20% for 86 and 88% of samples from the upper arm and fingerstick, respectively. Using correction factors of 1.3 for the upper-arm and 1.47 for finger-prick samples, 84 and 76% of the paired samples, respectively, were within ±20% for mycophenolic acid serum concentration. Patient experience surveys demonstrated limited pain and acceptable useability of the upper-arm device.
Tacrolimus and mycophenolic acid can be measured using 2 common VAMS devices with similar analytical performance. Patients are supportive of home-based monitoring with a preference for the Tasso-M20 device.
干血容量吸收微样本(VAMS)可以通过促进移植后的家庭采样来增强治疗药物监测。本研究旨在使用两种不同采样位置(Tasso-M20 在上臂和 Mitra 在手指)的 VAMS 设备对液相色谱-串联质谱法进行临床验证。还评估了患者的偏好。
通过比较配对 VAMS 和静脉血样,使用 Passing-Bablok 回归和 Bland-Altman 分析对他克莫司和霉酚酸进行临床验证。使用依赖于红细胞压积的公式和事先定义的固定校正因子将霉酚酸 VAMS 转换为血清浓度。使用既定问卷还调查了患者的观点,包括可用性、可接受性和可行性。
从 25 名肾移植受者中采集了配对样本(n=50)。对于全血浓度的他克莫司,分别有 86%和 88%的上臂和指端样本的差异在±20%以内。使用上臂样本的校正因子为 1.3,指端样本的校正因子为 1.47,分别有 84%和 76%的配对样本在±20%以内,霉酚酸血清浓度。患者体验调查表明,上臂装置疼痛有限且可用性可接受。
可以使用两种具有相似分析性能的常见 VAMS 设备来测量他克莫司和霉酚酸。患者支持家庭监测,对手套 M20 设备有偏好。