与在同一修复体下固定的较长种植体相比,超短(≤5.5毫米)种植体的临床性能:一项随机临床试验。

Clinical Performance of Extra-Short (≤5.5 mm) Compared to Longer Implants Splinted under the Same Prosthesis: A Randomized Clinical Trial.

作者信息

Anitua Eduardo, Montalvillo Adriana, Eguia Asier, Alkhraisat Mohammad Hamdan

机构信息

University Institute for Regenerative Medicine and Oral Implantology-UIRMI (UPV/EHU-Fundación Eduardo Anitua), 01007 Vitoria, Spain.

BTI Biotechnology Institute, 01005 Vitoria, Spain.

出版信息

Dent J (Basel). 2024 Sep 13;12(9):292. doi: 10.3390/dj12090292.

Abstract

This randomized controlled split-mouth trial compared the performance of 5.5 mm length implants (test group; TG) splinted within the same fixed prosthesis as longer implants (≥6.5 mm; control group; CG) in posterior regions. The primary hypothesis was that implant length does not affect marginal bone loss (MBL) one year post-implantation, while the secondary hypotheses included implant survival, peri-implant clinical variables, and prosthetic complications. Fifteen patients (eight males, seven females) with a mean age of 67 ± 9 years were included. No significant difference in the implant position between groups ( = 0.808) was observed. Implant diameters ranged from 3.00 to 4.25 mm, and the most common bone type was type I (67%). Bone density ( = 0.574) and implant insertion torque ( = 0.888) were similar between groups. Mesial MBL (mean: -0.1; range: -1.19 to 0.24 for TG, and -0.03; -1.75 to 0.45 for CG; = 0.955) and distal MBL (mean: -0.05; range: -1.41 to 0.27 for TG, and 0.08; -1.45 to 0.72 for CG; = 0.118) did not show statistical differences. There were no implant failures or technical complications. These findings suggest that 5.5 mm length implants could be a viable option for use in posterior regions, providing similar clinical outcomes to longer implants one year post-implantation.

摘要

这项随机对照的分口试验比较了5.5毫米长种植体(试验组;TG)与更长种植体(≥6.5毫米;对照组;CG)在同一固定修复体中用于后部区域的性能。主要假设是种植体长度在植入后一年不影响边缘骨丢失(MBL),而次要假设包括种植体存留率、种植体周围临床变量和修复并发症。纳入了15名患者(8名男性,7名女性),平均年龄为67±9岁。两组之间种植体位置无显著差异( = 0.808)。种植体直径范围为3.00至4.25毫米,最常见的骨类型为I型(67%)。两组之间的骨密度( = 0.574)和种植体植入扭矩( = 0.888)相似。近中MBL(平均值:-0.1;TG范围:-1.19至0.24,CG范围:-0.03;-1.75至0.45; = 0.955)和远中MBL(平均值:-0.05;TG范围:-1.41至0.27,CG范围:0.08;-1.45至0.72; = 0.118)未显示统计学差异。没有种植体失败或技术并发症。这些发现表明,5.5毫米长的种植体可作为用于后部区域的可行选择,在植入后一年提供与更长种植体相似的临床结果。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5983/11431532/b4ac78f71e56/dentistry-12-00292-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验