Suppr超能文献

量化视力和对比敏感度函数之间的功能关系。

Quantifying the Functional Relationship Between Visual Acuity and Contrast Sensitivity Function.

机构信息

Division of Arts and Sciences, NYU Shanghai, Shanghai, China.

Center for Neural Science, New York University, New York, New York, United States.

出版信息

Invest Ophthalmol Vis Sci. 2024 Oct 1;65(12):33. doi: 10.1167/iovs.65.12.33.

Abstract

PURPOSE

Studies have reported that individuals with certain ocular disorders may have significant decreases in contrast sensitivity function (CSF) despite having normal or near normal visual acuity (VA). This study seeks to elucidate this phenomenon by investigating the relationship between VA and CSF.

METHODS

We analyzed data from 14 eyes tested with Electronic Early Treatment Diabetic Retinopathy and quantitative CSF under four Bangerter foil conditions (n = 56). From the CSF data, we estimated peak gain, peak frequency, and contrast sensitivity acuity (CSA). We explored the correlations between VA and various CSF parameters and evaluated five predictive models of VA using CSA alone and in combination with additional CSF parameters through ridge regression.

RESULTS

We found that similar VA scores can correspond with markedly different CSFs and observed significant correlations among all CSF parameters and between VA and each CSF parameter (all P < 0.001). The most effective predictive model, incorporating CSA and peak gain, explained 90.97% of the variance with a root mean squared error of 0.0676 logMAR, which is comparable with the average standard deviation of the VA scores (0.0627 logMAR) and accounted for 38.6% of the residual variance not explained by the CSA-alone model.

CONCLUSIONS

This study offers the first empirical inference of the quantitative relationship between VA and CSF, suggesting that various CSF parameter combinations can yield identical VA. This might help to explain why some clinical populations with normal or near-normal VA exhibit significant CSF deficits and calls for further research in different clinical settings.

摘要

目的

已有研究报告称,尽管某些个体的视力正常或接近正常,但他们的对比敏感度功能(CSF)可能会显著降低。本研究旨在通过研究视力(VA)与 CSF 之间的关系来阐明这一现象。

方法

我们分析了在四种邦格特箔条件下(n = 56)接受电子早期糖尿病视网膜病变治疗和定量 CSF 测试的 14 只眼睛的数据。从 CSF 数据中,我们估计了峰值增益、峰值频率和对比敏感度视力(CSA)。我们探讨了 VA 与各种 CSF 参数之间的相关性,并通过脊回归评估了仅使用 CSA 以及将 CSA 与其他 CSF 参数相结合的五种 VA 预测模型。

结果

我们发现,相似的 VA 分数可能对应着明显不同的 CSF,并且观察到所有 CSF 参数之间以及 VA 与每个 CSF 参数之间都存在显著相关性(均 P < 0.001)。最有效的预测模型,纳入 CSA 和峰值增益,解释了 90.97%的方差,均方根误差为 0.0676 logMAR,与 VA 分数的平均标准偏差(0.0627 logMAR)相当,并解释了 CSA 单独模型无法解释的 38.6%的剩余方差。

结论

本研究首次对 VA 与 CSF 之间的定量关系进行了实证推断,表明各种 CSF 参数组合可以产生相同的 VA。这可能有助于解释为什么一些临床人群的 VA 正常或接近正常,但仍存在明显的 CSF 缺陷,并呼吁在不同的临床环境中进行进一步研究。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9513/11512569/067fed5b4dfe/iovs-65-12-33-f001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验