Suppr超能文献

一种由肋软骨和膨体聚四氟乙烯组成的榫卯结构在亚洲人鼻整形术中的应用:戴氏外源性延伸支架概念的应用Ⅱ

A Mortise and Tenon Framework Composed of Costal Cartilage and Expanded Polytetrafluoroethylene in Rhinoplasty for Asians: Application Ⅱ of Dai Exogenous Extension Stent Concept.

作者信息

Yu Bao-Fu, Wei Jiao, Dai Chuan-Chang

机构信息

Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.

出版信息

J Craniofac Surg. 2025 May 1;36(3):e292-e296. doi: 10.1097/SCS.0000000000010912. Epub 2024 Nov 25.

Abstract

BACKGROUND

The septum is often underdeveloped in East Asian populations, and traditional endogenous extension stents may not adequately fulfill the requirements for rhinoplasty. Herein, we present an innovative exogenous extension framework featuring a mortise and tenon structure specifically designed for East Asians.

METHODS

This framework comprises a mushroom-shaped rib cartilage component and a lancet-shaped expanded polytetrafluoroethylene (ePTFE) element, which are interconnected through a mortise and tenon design. The costal cartilage serves as a strut to support the nasal column and elevate the nasal tip. The ePTFE is utilized to augment the nasal dorsum and root, enhancing overall shape while being securely attached to the rib cartilage via the mortise and tenon structure. This configuration establishes a stable exogenous extension framework that also facilitates nose elongation. The safety and efficacy have been validated through over 10 years of clinical practice.

RESULTS

Over the past decade, we have performed this procedure in more than 500 cases without any complications, such as necrosis of the nasal column, ischemia of the nasal tip, or adverse graft appearances. Notable improvements in nasal morphology were observed across all patients. In addition, no postoperative restrictions on nasal ventilation were reported by any patient. Overall, patient satisfaction regarding surgical outcomes was exceptionally high.

CONCLUSIONS

This framework represents an advanced implementation of exogenous extension stent concept, which is particularly effective for East Asians since it does not require a well-developed nasal septum to provide support. In addition, it does not increase the risk of restricted nasal ventilation.

LEVEL OF EVIDENCE

Level IV.

摘要

背景

在东亚人群中,鼻中隔通常发育不全,传统的内源性延伸支架可能无法充分满足隆鼻手术的需求。在此,我们展示一种创新的外源性延伸框架,其具有专门为东亚人设计的榫卯结构。

方法

该框架由蘑菇形肋软骨组件和柳叶形膨体聚四氟乙烯(ePTFE)元件组成,它们通过榫卯设计相互连接。肋软骨作为支柱支撑鼻柱并抬高鼻尖。ePTFE用于增加鼻背和鼻根,在通过榫卯结构牢固地附着于肋软骨的同时增强整体形状。这种结构建立了一个稳定的外源性延伸框架,还便于延长鼻子。其安全性和有效性已通过超过10年的临床实践得到验证。

结果

在过去十年中,我们对500多例患者实施了该手术,未出现任何并发症,如鼻柱坏死、鼻尖缺血或移植外观不良。所有患者的鼻形态均有显著改善。此外,没有患者报告术后有鼻通气受限的情况。总体而言,患者对手术结果的满意度非常高。

结论

该框架代表了外源性延伸支架概念的先进应用,对东亚人特别有效,因为它不需要发育良好的鼻中隔来提供支撑。此外,它不会增加鼻通气受限的风险。

证据级别

四级。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验