Koga Hiroshi, Ishii Norito, Tsutsumi Masahiro, Teye Kwesi, Kosaka Mieko, Nakama Takekuni
Department of Dermatology, Kurume University School of Medicine, Fukuoka, Japan.
Kurume University Institute of Cutaneous Cell Biology, Fukuoka, Japan.
J Dermatol. 2025 Apr;52(4):744-748. doi: 10.1111/1346-8138.17647. Epub 2025 Feb 7.
Autoantibodies, including anti-BP180 and anti-BP230 antibodies in bullous pemphigoid (BP) and mucous membrane pemphigoid (MMP), and anti-type VII collagen (COL7) antibodies in epidermolysis bullosa acquisita (EBA), are well characterized. Enzyme-linked immunosorbent assays (ELISAs) for the detection of these antibodies in the serum are valuable for diagnosis. Previous studies have indicated that anti-BP180 and anti-BP230 antibodies in blister fluid and saliva can be detected using ELISA. The aim of this study was to detect anti-BP180, anti-BP230, and anti-COL7 antibodies in several types of samples, including blister fluid, an erosive surface swab, and saliva, by ELISAs and to compare the titers of these antibodies between different types of samples. Thirty-three patients with BP/MMP, two patients with EBA, and 13 patients with non-pemphigoid diseases were included in this study. Samples were collected from each patient and analyzed using commercial ELISA kits. In the cases of BP/MMP, the mean ± standard deviation indices of BP180 ELISA were 411.9 ± 538.3, 253.5 ± 333.3, 2.360 ± 1.714, and 1.599 ± 1.262, and those of BP230 ELISA were 27.73 ± 37.65, 20.52 ± 30.04, 0.486 ± 0.7915, and 0.346 ± 0.4373, from sera, blister fluids, erosive surface swabs, and saliva, respectively. The indices of BP180 and BP230 ELISAs using serum were significantly correlated with those of BP180 and BP230 ELISAs using blister fluid (r = 0.9342 and r = 0.9882), an erosive surface swab (r = 0.7586 and r = 0.9332), and saliva (r = 0.5731 and r = 0.6147), respectively. This study revealed that autoantibodies were detectable in blister fluids, erosive surfaces, and saliva, and their correlation with serum titers in pemphigoid diseases was highest in blister fluid. In summary, blister fluid can be a minimally invasive sample alternative to serum for the detection of pemphigoid-related antibodies.
自身抗体,包括大疱性类天疱疮(BP)和黏膜类天疱疮(MMP)中的抗BP180和抗BP230抗体,以及获得性大疱性表皮松解症(EBA)中的抗VII型胶原蛋白(COL7)抗体,已得到充分表征。用于检测血清中这些抗体的酶联免疫吸附测定(ELISA)对诊断很有价值。先前的研究表明,可用ELISA检测疱液和唾液中的抗BP180和抗BP230抗体。本研究的目的是通过ELISA检测疱液、糜烂面拭子和唾液等几种类型样本中的抗BP180、抗BP230和抗COL7抗体,并比较不同类型样本中这些抗体的滴度。本研究纳入了33例BP/MMP患者、2例EBA患者和13例非类天疱疮疾病患者。从每位患者采集样本,并使用商用ELISA试剂盒进行分析。在BP/MMP病例中,血清、疱液、糜烂面拭子和唾液中BP180 ELISA的平均±标准差指数分别为411.9±538.3、253.5±333.3、2.360±1.714和1.599±1.262,BP230 ELISA的指数分别为27.73±37.65、20.52±30.04、0.486±0.7915和0.346±0.4373。使用血清的BP180和BP230 ELISA指数分别与使用疱液(r = 0.9342和r = 0.9882)、糜烂面拭子(r = 0.7586和r = 0.9332)和唾液(r = 0.5731和r = 0.6147)的BP180和BP230 ELISA指数显著相关。本研究表明,在疱液、糜烂面和唾液中可检测到自身抗体,且在类天疱疮疾病中它们与血清滴度的相关性在疱液中最高。总之,疱液可作为一种微创样本替代血清用于检测类天疱疮相关抗体。