无结组织控制装置在神经外科颅脑和脊柱手术中的应用拓展。

Expanded applications of knotless tissue control devices in neurosurgical cranial and spinal applications.

作者信息

Tenhoeve Samuel A, Rawson Clayton, Tabachnick Dora R, Azab Mohammed A, Oladipo Omowumi, Karsy Michael

机构信息

Spencer Fox Eccles School of Medicine, University of Utah Salt Lake City UT USA.

College of Osteopathic Medicine, NOORDA College Provo UT USA.

出版信息

J Clin Neurosci. 2025 Apr;134:111108. doi: 10.1016/j.jocn.2025.111108. Epub 2025 Feb 8.

Abstract

OBJECTIVES

Effective wound closure is essential to neurosurgical procedures. Historical rates of neurosurgical wound complications range from 7 to 14 %. Knotless suturing with barbed sutures may offer effective closure rates but has had limited evaluation of safety in neurosurgical applications.

METHODS

Consecutive patients undergoing cranial, spinal, and peripheral nerve neurosurgical procedures from 12/2022 until 7/2024 were included in a quality improvement initiative. A retrospective review of demographics, past medical history, and operative and postoperative variables was undertaken. The primary outcome of interest was wound complications, including surgical site infection (SSI), dehiscence, or CSF leak. A cost analysis of suture treatment was also compared. A comparison to historical control rates (7%) was performed (one-sample proportional z-test).

RESULTS

A total of 195 consecutive patients were identified, with 10 wound-related complications including 3 superficial dehiscence treated with washout, 2 pseudomeningoceles, 2 cerebrospinal fluid leaks with meningitis, and 1 each of deep dehiscence with washout, superficial dehiscence with antibiotics, and epidural hematoma. A total of 53 (27.2 %) underwent cranial, 140 (71.8 %) spine, and 3 (1.0 %) peripheral nerve procedures. Ten patients (5.1 %) had incision complications with no difference to historical controls (p = 0.3). Cost analysis showed a range 0.35-3.03X cost differences using the knotless suture technique for different neurosurgical applications.

CONCLUSION

Knotless suture techniques can be an effective closure method for a variety of neurosurgical techniques comparable to expected wound complication rates. We expand on the potential applications of this technology compared with prior studies. Further studies will be necessary to confirm these findings.

摘要

目的

有效的伤口闭合对于神经外科手术至关重要。神经外科伤口并发症的历史发生率在7%至14%之间。使用倒刺缝线的免打结缝合可能提供有效的闭合率,但在神经外科应用中的安全性评估有限。

方法

2022年12月至2024年7月期间接受颅脑、脊柱和周围神经神经外科手术的连续患者被纳入一项质量改进计划。对人口统计学、既往病史以及手术和术后变量进行回顾性分析。主要关注的结果是伤口并发症,包括手术部位感染(SSI)、裂开或脑脊液漏。还比较了缝线治疗的成本分析。与历史对照率(7%)进行比较(单样本比例z检验)。

结果

共确定了195例连续患者,其中10例与伤口相关的并发症包括3例经冲洗治疗的浅表裂开、2例假性脑膜膨出、2例伴有脑膜炎的脑脊液漏,以及1例经冲洗的深部裂开、1例使用抗生素治疗的浅表裂开和1例硬膜外血肿。共有53例(27.2%)接受颅脑手术,140例(71.8%)接受脊柱手术,3例(1.0%)接受周围神经手术。10例患者(5.1%)有切口并发症,与历史对照组无差异(p = 0.3)。成本分析显示,使用免打结缝合技术在不同神经外科应用中的成本差异范围为0.35至3.03倍。

结论

免打结缝合技术对于各种神经外科技术而言,可以是一种有效的闭合方法,与预期的伤口并发症发生率相当。与先前的研究相比,我们扩展了该技术的潜在应用。需要进一步的研究来证实这些发现。