In vitro assessment of the accuracy of two intra-oral scanners for post space scanning in a fully digital workflow.

作者信息

Wahba Mennatallah, ElBasty Reham Said

机构信息

Fixed Prosthodontics Department, Faculty of Oral and Dental Medicine, Future University in Egypt, Cairo, Egypt.

Fixed Prosthodontics Department, Faculty of Dentistry, Cairo University, Cairo, Egypt.

出版信息

BMC Oral Health. 2025 Mar 19;25(1):407. doi: 10.1186/s12903-025-05723-x.

Abstract

BACKGROUND

With the rapid advancements in computer-aided imaging, the potential for chairside fabrication of custom-made posts utilizing intraoral scanners may offer a reliable alternative to traditional physical impressions. Accordingly, this study aimed to evaluate the accuracy (trueness and precision) of two intra-oral scanners when different post space diameters were employed. Additionally, the scan depth of each intra-oral scanner (IOS) was assessed.

METHODS

An endodontically treated mandibular canine was inserted in a printed typodont model and prepared with two post-space diameters; a small one (1.5 mm) and a large one (2 mm). Polyvinyl siloxane impressions for the two post-space diameters were taken and then scanned with an extra-oral scanner to serve as reference scans. Each post-space diameter was scanned using CEREC Primescan (n = 8) and Medit i700 (n = 8) intra-oral scanners. Standard tessellation language (STL) files of all intra-oral and extra-oral scans were uploaded to a 3D matching program to evaluate trueness, precision, and post-space length difference. Statistical analysis was performed using different tests for parametric and non-parametric data. The significance level was set at P < 0.05.

RESULTS

Regarding the effect of the IOS and the effect of the post-space diameter, both Medit i700 and the small diameter groups using both scanners showed significantly higher root mean square (RMS) values when evaluating trueness. For precision, Medit i700 showed a significantly higher RMS value in the large diameter group. Medit i700 showed a significantly higher difference in post-space length than Primescan in both diameters. Primescan recorded a zero difference in the large diameter group compared to the reference scan.

CONCLUSIONS

The IOS type and the post-space diameter influenced the scan accuracy and the depth of the scan. Accuracy results were superior when Primescan was implemented for scanning the large diameter post-space subgroup.

摘要

背景

随着计算机辅助成像技术的快速发展,利用口内扫描仪在椅旁制作定制桩核的可能性为传统物理印模提供了一种可靠的替代方法。因此,本研究旨在评估使用不同桩道空间直径时两种口内扫描仪的准确性(真实度和精密度)。此外,还评估了每种口内扫描仪(IOS)的扫描深度。

方法

将一颗经过根管治疗的下颌尖牙插入打印的牙列模型中,并制备两种桩道空间直径;一种较小的直径(1.5毫米)和一种较大的直径(2毫米)。获取两种桩道空间直径的聚乙烯基硅氧烷印模,然后用口外扫描仪进行扫描,作为参考扫描。每种桩道空间直径均使用CEREC Primescan(n = 8)和Medit i700(n = 8)口内扫描仪进行扫描。将所有口内和口外扫描的标准镶嵌语言(STL)文件上传到三维匹配程序中,以评估真实度、精密度和桩道空间长度差异。对参数数据和非参数数据使用不同的检验方法进行统计分析。显著性水平设定为P < 0.05。

结果

关于IOS的影响和桩道空间直径的影响,在评估真实度时,Medit i700以及使用两种扫描仪的小直径组均显示出明显更高的均方根(RMS)值。对于精密度,Medit i700在大直径组中显示出明显更高的RMS值。在两种直径下,Medit i700在桩道空间长度上的差异均比Primescan明显更大。与参考扫描相比,Primescan在大直径组中记录的差异为零。

结论

IOS类型和桩道空间直径影响扫描准确性和扫描深度。当使用Primescan扫描大直径桩道空间亚组时,准确性结果更佳。