Alotaibi Wafa M, Challa Naveen, Alrasheed Saif Hassan, Abanmi Rahaf Nasser
Department of Optometry and Visual Sciences, College of Applied Medicine Sciences, King Saud University, Riyadh, Saudi Arabia.
Department of Optometry, College of Applied Medical Sciences, Qassim University, Buraydah, Saudi Arabia.
PeerJ. 2025 Apr 1;13:e19227. doi: 10.7717/peerj.19227. eCollection 2025.
Assessment of eye parameters such as the white-to-white (WTW) corneal diameter, anterior chamber depth (ACD), and anterior chamber angle (ACA) are essential for preoperative evaluation of refractive surgery and diagnosing and managing some ocular diseases.
To report the distribution and association between white-to-white corneal diameter and anterior chamber parameters in the Saudi adult population.
Cross-sectional prospective study consisting of 82 Saudi adults. White-to-white corneal diameter, anterior chamber angle, anterior chamber depth, and axial length were collected from healthy subjects using the Pentacam AXL Wave in a tertiary eye care setting.
Mean white-to-white corneal diameter, anterior chamber angle, anterior chamber depth, and axial length were 11.95 ± 0.39 mm, 37.94 ± 5.01°, 2.97 ± 0.31 mm and 23.93 ± 0.97 mm, respectively. A significant moderate correlation was found between white-to-white corneal diameter and anterior chamber angle (r = 0.31, ≤ 0.01), anterior chamber depth (r = 0.49, ≤ 0.01), and axial length (r = 0.50, ≤ 0.01) and between anterior chamber angle and anterior chamber depth (r = 0.71, ≤ 0.01). Furthermore, age was moderately correlated with anterior chamber angle (r = 0.44, 0.01) and anterior chamber depth (r = 0.39, 0.01) and weakly correlated with white-to-white corneal diameter (r =0.17, = 0.12). Males had a significantly ( < 0.01) higher white-to-white corneal diameter (12.12 ± 0.38 mm) than females (11.84 ± 0.36.mm).
Reference values for white-to-white corneal diameter and anterior chamber parameters would help eye care professionals choose the right lenses for cataract and refractive surgeries as well as in diagnosing glaucoma and corneal disorders.
评估诸如白到白(WTW)角膜直径、前房深度(ACD)和前房角(ACA)等眼部参数对于屈光手术的术前评估以及某些眼部疾病的诊断和管理至关重要。
报告沙特成年人群中白到白角膜直径与前房参数之间的分布及相关性。
对82名沙特成年人进行横断面前瞻性研究。在三级眼科护理机构中,使用Pentacam AXL Wave从健康受试者收集白到白角膜直径、前房角、前房深度和眼轴长度。
白到白角膜直径、前房角、前房深度和眼轴长度的平均值分别为11.95±0.39毫米、37.94±5.01°、2.97±0.31毫米和23.93±0.97毫米。发现白到白角膜直径与前房角(r = 0.31,P≤0.01)、前房深度(r = 0.49,P≤0.01)和眼轴长度(r = 0.50,P≤0.01)之间以及前房角与前房深度之间(r = 0.71,P≤0.01)存在显著的中度相关性。此外,年龄与前房角(r = 0.44,P<0.01)和前房深度(r = 0.39,P<0.01)中度相关,与白到白角膜直径弱相关(r = 0.17,P = 0.12)。男性的白到白角膜直径(12.12±0.38毫米)显著高于女性(11.84±0.36毫米)(P<0.01)。
白到白角膜直径和前房参数的参考值将有助于眼科护理专业人员为白内障和屈光手术选择合适的晶状体,以及诊断青光眼和角膜疾病。