PURPOSE

To investigate the approximal abrasive enamel and dentine wear using interdental brushes (IDBs) with and without toothpaste in a novel standardised in-vitro set-up.

MATERIALS AND METHODS

Seventy-two bovine enamel and 72 dentine specimens were prepared and randomly allocated into 12 groups (odd group: dentine; even group: enamel). The specimens were brushed with three IDB types of ISO 2 (Curaprox (CPS09, groups 1-4), Elmex (size 2, groups 5-8) and Circum (Circum 2, groups 9-12)) with artificial saliva or toothpaste slurry (Colgate Total Original). A custom-made brushing device simulated interdental brushing for 1 h on dentine (7,200 strokes) and 6 h on enamel (43,200 strokes). Wear was assessed using a contact profilometer, and electron microscopy images were taken. Kruskal-Wallis and Mann-Whitney tests were used for statistical analysis.

RESULTS

The combination of IDBs with artificial saliva resulted in enamel and dentine wear below the detection limit, similar to the enamel wear when toothpaste was used. Dentine specimens showed significant abrasive wear, which was influenced by the IDBs' design as follows: Curaprox (median ± interquartile range (IQR): 8.6 ± 1.0 µm), Circum (9.7 ± 2.9 µm), and Elmex (18.8 ± 9.1 µm). The difference in wear between Curaprox and Circum was not statistically significant (P = 1). However, the increase in the wear of Elmex compared with that of the other IDBs was significant (P 0 0.001).

CONCLUSION

The use of IDBs with toothpaste may cause statistically significant dentine wear and should not be recommended in combination. Appropriate instructions are essential.

摘要

目的

在一种新型标准化体外实验装置中,研究使用带牙膏和不带牙膏的牙间刷(IDB)时邻面釉质和牙本质的磨损情况。

材料与方法

制备72个牛牙釉质标本和72个牙本质标本,并随机分为12组(奇数组:牙本质;偶数组:釉质)。使用三种ISO 2型牙间刷(Curaprox(CPS09,第1 - 4组)、Elmex(2号尺寸,第5 - 8组)和Circum(Circum 2,第9 - 12组)),分别蘸取人工唾液或牙膏糊剂(高露洁全效原味牙膏)对标本进行刷牙。定制的刷牙装置在牙本质上模拟牙间刷牙1小时(7200次刷动),在釉质上模拟6小时(43200次刷动)。使用接触式轮廓仪评估磨损情况,并拍摄电子显微镜图像。采用Kruskal - Wallis检验和Mann - Whitney检验进行统计分析。

结果

牙间刷与人工唾液组合导致釉质和牙本质磨损低于检测限,这与使用牙膏时的釉质磨损情况相似。牙本质标本显示出显著的磨蚀性磨损,其受牙间刷设计的影响如下:Curaprox(中位数±四分位数间距(IQR):8.6±1.0 µm)、Circum(9.7±2.9 µm)和Elmex(18.8±9.1 µm)。Curaprox和Circum之间的磨损差异无统计学意义(P = 1)。然而,与其他牙间刷相比,Elmex的磨损增加具有显著性(P < 0.001)。

结论

牙间刷与牙膏一起使用可能会导致具有统计学意义的牙本质磨损,不应推荐联合使用。适当的使用说明至关重要。