Suppr超能文献

使用FLIR T560进行数字红外热成像视频在检测与I型复杂性区域疼痛综合征相关的体温过低中的应用:一份符合CARE标准的病例报告。

Usefulness of digital infrared thermography video using FLIR T560 in detecting hypothermia associated with complex regional pain syndrome type I: A CARE-compliant case report.

作者信息

Jang Yewon, Kim Sungho, Chang Min Cheol

机构信息

Department of Electronic Engineering, Yeungnam University, Gyeongsan-si, Republic of Korea.

Department of Physical Medicine and Rehabilitation, College of Medicine, Yeungnam University, Daegu, Republic of Korea.

出版信息

Medicine (Baltimore). 2025 Jun 20;104(25):e41876. doi: 10.1097/MD.0000000000041876.

Abstract

RATIONALE

Because the diagnosis of complex regional pain syndrome (CRPS) majorly relies on patients' subjective clinical complaints, CRPS can be overdiagnosed, underdiagnosed, or missed entirely in clinical practice. CRPS is related to dysfunction of the autonomic nervous system, which causes temperature changes in patients' skin. This case report evaluates the effectiveness of the FLIR T560 portable thermal imaging camera in detecting hypothermia associated with CRPS type I, potentially enhancing diagnostic accuracy.

PATIENT CONCERNS

We present a 25-year-old female with pain and limited passive range of motion in all parts of her hands bilaterally for 7 months. The bilateral hand pain was aggravated by active and passive range of motion. Also, the patient had bilateral hyperesthesia and allodynia of her entire hands, and skin atrophy and hypohidrosis were observed on both hands. The skin color of both hands was relatively cyanotic. Stiffness was checked during the passive range of motion of her bilateral fingers. Additionally, mild motor weakness was checked on the finger flexor and extensor bilaterally.

DIAGNOSES

The patient was diagnosed with CRPS type I. The FLIR T560 was used to record thermal images in an insulated room, revealing a lower surface temperature (approximately 1°C-2°C difference), shown as less bright, on her bilateral hands and forearms compared with a normal subject.

INTERVENTIONS

We administered Pregabalin 50 mg oral medication twice daily and the contrast bath.

OUTCOMES

At 1-month-follow up, about 50% of her pain was reduced.

LESSONS

We demonstrate that the FLIR T560 thermal imaging camera can show hypothermia on the hands bilaterally in CRPS type I, which can be helpful for the accurate diagnosis of CRPS. The FLIR T560 camera is a portable and convenient tool that may support the diagnosis of CRPS.

摘要

原理

由于复杂性区域疼痛综合征(CRPS)的诊断主要依赖于患者的主观临床症状,因此在临床实践中,CRPS可能会被过度诊断、诊断不足或完全漏诊。CRPS与自主神经系统功能障碍有关,这会导致患者皮肤温度变化。本病例报告评估了FLIR T560便携式热成像相机在检测与I型CRPS相关的体温过低方面的有效性,可能会提高诊断准确性。

患者情况

我们报告一名25岁女性,双侧手部各部位疼痛且被动活动范围受限7个月。主动和被动活动范围会加重双侧手部疼痛。此外,患者双手出现双侧感觉过敏和痛觉过敏,双手均观察到皮肤萎缩和少汗。双手皮肤颜色相对发绀。在双侧手指被动活动时检查了僵硬情况。此外,还双侧检查了手指屈肌和伸肌的轻度肌无力情况。

诊断

患者被诊断为I型CRPS。使用FLIR T560在隔热房间记录热成像,结果显示与正常受试者相比,其双侧手部和前臂的表面温度较低(相差约1°C - 2°C),表现为亮度较低。

干预措施

我们给予患者每日两次口服50毫克普瑞巴林并进行对比浴。

结果

在1个月的随访中,她的疼痛减轻了约50%。

经验教训

我们证明FLIR T560热成像相机可以显示I型CRPS患者双侧手部体温过低,这有助于CRPS的准确诊断。FLIR T560相机是一种便携式且方便的工具,可能有助于CRPS的诊断。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/39fc/12187355/a895606b28e0/medi-104-e41876-g001.jpg