Suppr超能文献

聚焦种植体周围美学:在一项随机临床试验中比较阳极氧化钛基台和二氧化锆基台

Peri-Implant Esthetics in Focus: Comparing Anodized Titanium and Zirconium Dioxide Abutments in a Randomized Clinical Trial.

作者信息

Agarwal Sakshi, Durrani Farhan, Pandey Aishwarya, Rashika M, Shilpi Shraddha, Meena Dhanraj

机构信息

Unit of Periodontology, Faculty of Dental Sciences, Institute of Medical Sciences, Banaras Hindu University, Varanasi, India.

出版信息

J Esthet Restor Dent. 2025 Jul 16. doi: 10.1111/jerd.13515.

Abstract

OBJECTIVE

Achieving optimal esthetics remains challenging due to limited comparative evidence between pink-anodized titanium and zirconium dioxide abutments. The objective of this clinical study was to evaluate the optical outcomes of pink-anodized titanium and zirconium dioxide abutments in the esthetic region.

METHODS

Twenty-two subjects with an edentulous site in the maxillary esthetic region with a tooth present mesially and distally were selected for implant surgery along with hard and soft tissue augmentation. Group A received a pink-anodized titanium abutment with a layered lithium disilicate single crown. Group B received a zirconium dioxide abutment with the same prosthesis material. The contralateral natural tooth served as the control group. Optical outcomes were assessed using a spectrophotometer. The CIELAB color coordinates (Commission Internationale de l'Eclairage) were recorded to calculate ΔE values. Vernier calipers, along with an endodontic file, were used to measure the peri-implant soft tissue thickness. The Pink Esthetic Score (PES) was evaluated using digital images of 22 single-tooth implant crowns to assess the surrounding soft tissue esthetics.

RESULTS

Zirconia abutments (Group A) demonstrated superior optical outcomes compared to pink-anodized titanium abutments (Group B). The ΔE values for Group A at the peri-implant soft tissue, coronal, and midfacial crown levels were significantly lower compared to Group B. Soft tissue thickness (STT) increased over time in both groups, with a slight increase in Group B. The Pink Esthetic Score (PES) also improved with recall visits at each evaluation.

CONCLUSION

Zirconia abutments provided superior esthetic outcomes compared to pink-anodized titanium abutments, with significantly lower color differences (ΔE) and higher Pink Esthetic Scores (PES). Although pink-anodized titanium abutments showed increased soft tissue thickening with time, zirconia abutments remained the more favorable option for esthetically demanding cases.

CLINICAL TRIALS REGISTRY

(CTRI No. CTRI/2024/03/064442).

摘要

目的

由于粉色阳极氧化钛基台和二氧化锆基台之间的比较证据有限,实现最佳美学效果仍然具有挑战性。本临床研究的目的是评估粉色阳极氧化钛基台和二氧化锆基台在美学区域的光学效果。

方法

选择22名上颌美学区域有缺牙部位、近远中均有牙齿的受试者进行种植手术,并进行软硬组织增量。A组接受带有分层锂 disilicate 单冠的粉色阳极氧化钛基台。B组接受相同修复材料的二氧化锆基台。对侧天然牙作为对照组。使用分光光度计评估光学效果。记录CIELAB颜色坐标(国际照明委员会)以计算ΔE值。使用游标卡尺和根管锉测量种植体周围软组织厚度。使用22个单颗牙种植体冠的数字图像评估粉色美学评分(PES),以评估周围软组织美学。

结果

与粉色阳极氧化钛基台(B组)相比,氧化锆基台(A组)表现出更好的光学效果。A组在种植体周围软组织、冠部和中面部冠水平的ΔE值明显低于B组。两组的软组织厚度(STT)均随时间增加,B组略有增加。每次随访时粉色美学评分(PES)也有所改善。

结论

与粉色阳极氧化钛基台相比,氧化锆基台提供了更好的美学效果,颜色差异(ΔE)明显更低,粉色美学评分(PES)更高。尽管粉色阳极氧化钛基台随着时间的推移显示出软组织增厚增加,但氧化锆基台仍然是美学要求较高病例的更有利选择。

临床试验注册

(CTRI编号CTRI/2024/03/064442)。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验