MacNamara E, Clarke S, McCann S R
J Clin Pathol. 1984 Jun;37(6):669-72. doi: 10.1136/jcp.37.6.669.
The Imugard IG 500 cotton wool filter and the Cellselect cellulose acetate filter were adapted for filtration of leucocytes from packed cell transfusions at the bedside. Sixty five transfusions were given via the Imugard IG 500 filter and 54 transfusions were given via the Cellselect filter. Packed red cell concentrates from the National Blood Transfusion Service provided for routine blood transfusions were used in all cases. No patient in either group of multitransfused patients experienced a febrile blood transfusion reaction during the study. The Imugard IG 500 removed 91% +/- 9 (SEM) leucocytes; the Cellselect removed 96% +/- 7 (SEM) leucocytes. In the Imugard IG 500 group one patient received greater than 0.5 X 10(9) leucocytes. In the Imugard IG 500 group one patient received greater than 0.5 X 10(9) leucocytes, but no patient in the Cellselect group received greater than 0.5 X 10(9) leucocytes in any single transfusion. This is a safe method of providing leucocyte poor blood at the bedside.
Imugard IG 500脱脂棉过滤器和Cellselect醋酸纤维素过滤器适用于在床边对浓缩红细胞输血进行白细胞过滤。通过Imugard IG 500过滤器进行了65次输血,通过Cellselect过滤器进行了54次输血。所有病例均使用了国家输血服务中心提供的用于常规输血的浓缩红细胞。在研究期间,两组多次输血患者中均无患者发生发热性输血反应。Imugard IG 500过滤器去除了91%±9(标准误)的白细胞;Cellselect过滤器去除了96%±7(标准误)的白细胞。在Imugard IG 500组中,有1例患者接受的白细胞超过0.5×10⁹个。在Imugard IG 500组中,有1例患者接受的白细胞超过0.5×10⁹个,但在Cellselect组中,没有患者在任何一次输血中接受的白细胞超过0.5×10⁹个。这是一种在床边提供少白细胞血液的安全方法。