Wight T A, Grisius R J, Gaugler R W
J Prosthet Dent. 1980 Apr;43(4):415-8. doi: 10.1016/0022-3913(80)90212-7.
All the vented samples with sprue widths of 2 mm or more were defect free, whereas the corresponding unvented samples had extensive voids and porosity in all but one casting. All castings with a sprue width of 1 mm were defective regardless of whether or not vents were used. The thickness of the investment above the pattern had no effect on casting results.