Suppr超能文献

空气中2,4,5-T丙二醇丁醚酯的固体吸收剂收集及气相色谱测定

Solid absorbent collection and gas chromatographic determination of the propylene glycol butyl ether esters of 2,4,5-T in air.

作者信息

Langhorst M L

出版信息

Am Ind Hyg Assoc J. 1980 May;41(5):328-33. doi: 10.1080/15298668091424834.

Abstract

A method has been developed and validated for the collection of the propylene glycol butyl ether esters of 2,4,5-trichlorophenoxyacetic acid (2,4,5-T) in air and their determination by gas chromatography with electron capture detection. The samples are collected on XAD-2 resin, desorbed in diethyl ether prior to analysis. The procedure is designed for industrial hygiene monitoring to provide an accurate 4 hour time-weighted average of the exposure level. Recoveries were found to be 97 +/- 8% (2 sigma) for the propylene glycol butyl ether esters of 2,4, 5-T in the concentration range of 0.70 ppb (v/v) to 5.00 ppm (v/v). Breakthrough concentrations, storage effects and humidity effects were also investigated.

摘要

已开发并验证了一种用于收集空气中2,4,5-三氯苯氧基乙酸(2,4,5-T)的丙二醇丁醚酯并通过带有电子捕获检测的气相色谱法进行测定的方法。样品收集在XAD-2树脂上,分析前用乙醚解吸。该程序旨在用于工业卫生监测,以提供暴露水平的准确4小时时间加权平均值。在0.70 ppb(v/v)至5.00 ppm(v/v)的浓度范围内,2,4,5-T的丙二醇丁醚酯的回收率为97±8%(2σ)。还研究了穿透浓度、储存效应和湿度效应。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验