Abstract

The flux of radioactive urate from bath to lumen was measured in isolated proximal convoluted (PCT), proximal straight (PST), and cortical collecting tubules (CCT). Urate was secreted in the PST as evinced by a) accumulation of urate in the lumen of perfused tubules to levels 2-4 times greater than in the bath, and b) inhibition of urate flux (bath to lumen) by cooling, by probenecid (2.5 X 10(-4) M), and by ouabain (10(-4) M). Urate secretion was strongly dependent on the rate of urinary flow, diminishing as flow rate was reduced below 2 nl/min, and reaching maximal rates when flow exceeded 5 nl/min. The isotopic urate (either [2-14C]urate or [6-14C]urate) was secreted without modification. Luminal urate was not impressively elevated above the concentration of the bath in PCT. Cortical collecting tubules were relatively impermeable to urate. It is concluded that urate secretion occurs predominantly in the PST of this species by a mechanism dependent on the uphill transport of the molecule from the bath into the urine.

摘要

在离体的近端曲管(PCT)、近端直小管(PST)和皮质集合管(CCT)中测量了放射性尿酸盐从管周液到管腔的通量。尿酸盐在PST中分泌,这表现为:a)灌注小管管腔中尿酸盐的积累达到比管周液中高2至4倍的水平;b)冷却、丙磺舒(2.5×10⁻⁴M)和哇巴因(10⁻⁴M)可抑制尿酸盐通量(从管周液到管腔)。尿酸盐分泌强烈依赖于尿流速率,当流速降至2 nl/min以下时分泌减少,当流速超过5 nl/min时达到最大速率。同位素尿酸盐([2-¹⁴C]尿酸盐或[6-¹⁴C]尿酸盐)未经修饰即被分泌。近端曲管管腔中的尿酸盐浓度并未显著高于管周液。皮质集合管对尿酸盐相对不通透。结论是,该物种的尿酸盐分泌主要发生在近端直小管,其机制依赖于分子从管周液到尿液的上坡转运。