Lafont N D, Kostucki W M, Marchand P H, Michaux M N, Boogaerts J G
Department of Anesthesiology and Intensive Care, Reine Fabiola Hospital, Montignies-sur-Sambre, Belgium.
Can J Anaesth. 1994 Sep;41(9):850-3. doi: 10.1007/BF03011592.
This case report demonstrates embolization of echogenic material detected by transoesophageal echocardiography during a cemented total hip arthroplasty in a 76-yr-old woman without patent foramen ovale. During the placement of the acetabular and femoral components, and during relocation of the hip joint, a "snow flurry" appearing in the right atrium was followed by several highly echogenic and mobile emboli of various sizes, some of them with a vermiform shape 1 to 5 cm long. At skin closure, echogenic material was seen in the right branch of the pulmonary artery adherent to the vascular wall of the bifurcation of the main pulmonary artery. No changes were observed in any haemodynamic variable monitored (heart rate, systemic and right atrial pressures). Also, no desaturation was detected by pulse oximetry and blood gases at the time of embolism and there was no decrease in PETCO2. This case report is in line with other studies which failed to show a haemodynamic impact of TEE detected emboli during THA.
本病例报告展示了在一名76岁无卵圆孔未闭的女性患者行骨水泥型全髋关节置换术期间,经食管超声心动图检测到的回声物质栓塞情况。在髋臼和股骨假体置入过程中以及髋关节复位时,右心房出现“雪花”样表现,随后出现多个大小各异、高度回声且可移动的栓子,其中一些呈1至5厘米长的蠕虫状。在皮肤缝合时,可见肺动脉右支有回声物质附着于主肺动脉分叉处的血管壁。监测的任何血流动力学变量(心率、体循环和右心房压力)均未观察到变化。此外,在栓塞时通过脉搏血氧饱和度仪和血气分析未检测到氧饱和度下降,呼气末二氧化碳分压也未降低。本病例报告与其他研究一致,这些研究未能显示经食管超声心动图检测到的栓子在全髋关节置换术中对血流动力学有影响。