Suppr超能文献

[新鲜同种异体动脉移植作为人工血管感染时主动脉-髂动脉-股动脉血管置换术]

[Fresh homologous arterial transplant as aorto-iliac-femoral vascular replacement in prosthesis infection].

作者信息

Kniemeyer H W, Torsello G, Hennes N, Grabitz K, Sandmann W

机构信息

Klinik f. Gefässchirurgie und Nierentransplantation, Heinrich-Heine-Universität Düsseldorf.

出版信息

Vasa. 1994;23(3):268-73.

PMID:7975875
Abstract

A patient with late graft infection in the groin following aorto-bifemoral-Dacron-bypass and recurrent infection of extra-anatomic bypasses is presented. Despite the evidence or graft infection (by preoperative imaging studies and intraoperative perigraft purulence) cultures did not identify the infective organism. Retrospectively a graft infection with Staphylococcus epidermidis is supposed as the most likely cause. A graft replacement with freshly harvested, not cryopreserved arterial homograft was performed. The perfusion of the extremities was excellent, the wounds healed perfectly. In special indications freshly harvested cadaveric arterial homografts are an acceptable substitute for infected aorto-femoral grafts.

摘要

本文介绍了一名患者,其在主动脉-双股-涤纶旁路手术后腹股沟出现晚期移植物感染,且解剖外旁路反复感染。尽管有移植物感染的证据(通过术前影像学研究和术中移植物周围脓性渗出),但培养未鉴定出感染病原体。回顾性推测最可能的原因是表皮葡萄球菌引起的移植物感染。进行了新鲜获取、未冷冻保存的动脉同种异体移植物置换术。肢体灌注良好,伤口愈合完美。在特殊情况下,新鲜获取的尸体动脉同种异体移植物是感染性主动脉-股动脉移植物的可接受替代物。