Suppr超能文献

视神经炎的视野轮廓。视神经炎治疗试验的一年随访。

Visual field profile of optic neuritis. One-year follow-up in the Optic Neuritis Treatment Trial.

作者信息

Keltner J L, Johnson C A, Spurr J O, Beck R W

机构信息

University of California-Davis.

出版信息

Arch Ophthalmol. 1994 Jul;112(7):946-53. doi: 10.1001/archopht.1994.01090190094027.

Abstract

PURPOSE

The purpose of this present study was to evaluate longitudinal visual field information for 448 patients over their first year of follow-up in the Optic Neuritis Treatment Trial.

METHODS

We reviewed 6536 automated static visual fields performed on a visual field analyzer (Humphrey Visual Field Analyzer) at nine visits within the 1-year period for each of the patients.

RESULTS

The median values of the mean deviations for affected eyes were as follows: -22.88 dB at baseline, -1.94 dB at 6 months, and -1.62 dB at 1 year. At 6 months, 51% of affected eye visual fields were normal, and at 1 year 55.9% were normal. Approximately two thirds (68.8%) of the fellow eyes were classified as abnormal at baseline, although the defects were generally slight. One third (33.2%) were abnormal at 6 months, and approximately one third were still abnormal at 1 year. More than 87% of those abnormal at 6 months and at 1 year had been abnormal at baseline. Binocular analysis revealed that 13.2% of patients showed a chiasmal or retrochiasmal type of field defect at least once during the year (5.1% bitemporal; 8.9% homonymous). Of the patients who showed a retrochiasmal visual field defect, 75.7% had an abnormal magnetic resonance imaging scan at baseline compared with 46% of the rest of the patients in the Optic Neuritis Treatment Trial (chi 2 = 10.73, df = 1, P < .002).

CONCLUSION

Over the first year of follow-up, the majority of patients with visual field defects from acute optic neuritis returned to normal, as measured by automated static perimetry. Many fields showed variation in the pattern and location of the sensitivity loss. Chiasmal and retrochiasmal defects occurred more commonly than previously reported.

摘要

目的

本研究旨在评估448例视神经炎治疗试验患者在随访第一年的纵向视野信息。

方法

我们回顾了每位患者在1年期间9次就诊时使用视野分析仪(Humphrey视野分析仪)进行的6536次自动静态视野检查。

结果

患眼平均偏差的中位数如下:基线时为-22.88 dB,6个月时为-1.94 dB,1年时为-1.62 dB。6个月时,51%的患眼视野正常,1年时55.9%正常。尽管缺陷通常较轻,但约三分之二(68.8%)的对侧眼在基线时被分类为异常。6个月时三分之一(33.2%)异常,1年时约三分之一仍异常。6个月和1年时异常的患者中,超过87%在基线时就已异常。双眼分析显示,13.2%的患者在这一年中至少有一次出现交叉性或交叉后性视野缺损(5.1%为双颞侧;8.9%为同侧)。在出现交叉后性视野缺损的患者中,75.7%在基线时磁共振成像扫描异常,而视神经炎治疗试验中其余患者为46%(χ2 = 10.73,自由度 = 1,P <.002)。

结论

在随访的第一年,通过自动静态视野检查测量,大多数急性视神经炎视野缺损患者恢复正常。许多视野在敏感度丧失的模式和位置上存在变化。交叉性和交叉后性缺损的发生比以前报道的更常见。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验