Because of Eustachian tube controls middle ear pressure to maintain the best hearing level, we tested the equilibration capacity of the Eustachian tube by measuring hearing levels in a soundproof pressure chamber. The number of swallows to recover normal hearing after the chamber pressure reached -200 mm H2O (an index of equilibration capacity for the static pressure differences across the eardrum) was less than 9 in normal subjects. The worst level of hearing and the time required to recover normal hearing from the beginning of alteration in the chamber pressure to -700 mm H2O (indexes of equilibration capacity for dynamic pressure differences across the eardrum) were 0-17 dB and within 120s in normal subjects. It was difficult to determine definitive normal ranges of the equilibrium capacity of the Eustachian tube when positive pressure was applied.

摘要

由于咽鼓管控制中耳压力以维持最佳听力水平,我们通过在隔音压力舱中测量听力水平来测试咽鼓管的平衡能力。当舱内压力达到-200 mm H2O(鼓膜两侧静压差异平衡能力的指标)后,恢复正常听力所需的吞咽次数在正常受试者中少于9次。听力最差水平以及从舱内压力开始变化到-700 mm H2O(鼓膜两侧动压差异平衡能力的指标)恢复正常听力所需的时间在正常受试者中分别为0 - 17 dB和120秒以内。当施加正压时,很难确定咽鼓管平衡能力的确切正常范围。