Abstract

Recently, the in vivo cavitation potential has become a primary concern among manufacturers of new mechanical heart valves (MHV). An experimental/computational program was designed to investigate each of the flow parameters involved. It was established that the closing velocity of the leaflet holds the key to MHV cavitation. One of the novel concepts of the new bileaflet mechanical heart valve (1205-MHV) was its ability to operate with a relatively small angular excursion that led to a much smaller closure velocity at impact (as compared with control valves). This is believed to significantly reduce the cavitation potential. The 1205-MHV is characterized by a longer valve body, with the hinges protruding further upstream. The unique design allows the valve the freedom to open as much as 90 degrees. The closure velocities are reduced by a smaller leaflet excursion (50 degrees), combined with a floating hinge that allows absorption of part of the impact energy at closure. The impact velocities of the 1205-MHV leaflets at closure were measured by a laser sweeping technique that monitored the leaflet closing motion with a precision of 5 microseconds within the last 3 degrees before impact. The 27 mm 1205-MHV (the largest size) was tested in the program by mounting the valve in the mitral position of a physiologic mock circulatory loop. The valve was tested at 70, 90, and 120 bpm. The results were compared with those of a St. Jude Medical 29 mm MHV. The closure velocities measured with the 1205-MHV were significantly lower than those measured with the control valve.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

最近,体内空化潜能已成为新型机械心脏瓣膜(MHV)制造商主要关注的问题。设计了一个实验/计算程序来研究每个相关的流动参数。已确定瓣叶的关闭速度是机械心脏瓣膜空化的关键。新型双叶机械心脏瓣膜(1205-MHV)的新颖概念之一是其能够以相对较小的角行程运行,这导致撞击时的关闭速度小得多(与对照瓣膜相比)。据信这可显著降低空化潜能。1205-MHV的特点是阀体较长,铰链向上游突出更远。独特的设计使瓣膜能够自由打开达90度。较小的瓣叶行程(50度)与允许在关闭时吸收部分撞击能量的浮动铰链相结合,降低了关闭速度。1205-MHV瓣叶关闭时的撞击速度通过激光扫描技术测量,该技术在撞击前最后3度内以5微秒的精度监测瓣叶关闭运动。通过将瓣膜安装在生理模拟循环回路的二尖瓣位置,在该程序中测试了27mm的1205-MHV(最大尺寸)。在70、90和120次/分钟的心率下对瓣膜进行了测试。将结果与圣犹达医疗29mm机械心脏瓣膜的结果进行了比较。用1205-MHV测量的关闭速度明显低于用对照瓣膜测量的速度。(摘要截短为250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验