Abstract

The nature of bladder electrical activity was investigated in anaesthetised cats and 1 baboon. A time-locked muscle response to sacral ventral root stimulation was most clearly detected within a 10-40 Hz frequency band, the response preceding the rise in intravesical pressure. During reflex voiding only activity in the 10-40 Hz band was consistently related to reflex voiding and to the small contractions leading up to voiding. It is concluded that only a very limited part of the wide band electrical activity recorded from the bladder can be considered genuine electromyogram and that the 10-40 Hz frequency band probably excludes the worst of the artefact. Possible sources of artefact and their relation to changes in intravesical pressure are presented in Table I.

摘要

在麻醉猫和1只狒狒身上研究了膀胱电活动的性质。对骶神经前根刺激的时间锁定肌肉反应在10 - 40赫兹频段内最清晰可测,该反应先于膀胱内压升高。在反射性排尿期间,只有10 - 40赫兹频段的活动始终与反射性排尿以及导致排尿的小收缩相关。得出的结论是,从膀胱记录的宽带电活动中只有非常有限的一部分可被视为真正的肌电图,并且10 - 40赫兹频段可能排除了最严重的伪迹。表I列出了伪迹的可能来源及其与膀胱内压变化的关系。