Sahlin S, Chen E
St Erik's Eye Hospital, Karolinska Institute, Stockholm, Sweden.
Am J Ophthalmol. 1997 Dec;124(6):758-64. doi: 10.1016/s0002-9394(14)71692-7.
To investigate the influence of gravity and blink rate on lacrimal drainage capacity and to learn whether lacrimal pump function can be measured with the drop test.
The drop test for lacrimal drainage capacity was performed in 20 test subjects, aged 12 to 30 years. Drops of a known volume of lukewarm saline solution were repeatedly instilled in the tear film for 3 minutes. Excessive saline solution was then removed, and the volume drained by the lacrimal passages was calculated. The drop test was performed both with the nasolacrimal duct in a 45-degree position and with the nasolacrimal duct in a horizontal position. The drop test was performed two times in each position, with the individual reading and not reading. A lower blink rate was induced by reading.
There was a high correlation between blink rate and lacrimal drainage when the nasolacrimal duct was in a horizontal position. The volume drained with each blink was approximately 2 microliters. However, when gravity acted upon the fluid in the lacrimal sac-nasolacrimal duct in the direction of the tear flow, the lacrimal drainage capacity showed a significant but variable increase, and there was no significant correlation between blink rate and lacrimal drainage capacity.
Lacrimal drainage capacity in young individuals was significantly affected by both blink rate and gravity. Lacrimal pump function can be measured quantitatively with the drop test.
研究重力和眨眼频率对泪液引流能力的影响,并了解是否可以通过滴液试验来测量泪泵功能。
对20名年龄在12至30岁的受试者进行泪液引流能力的滴液试验。将已知体积的温生理盐水滴反复滴入泪膜中,持续3分钟。然后去除多余的生理盐水,并计算泪道排出的液体体积。分别在鼻泪管处于45度位置和水平位置时进行滴液试验。每个位置进行两次滴液试验,一次受试者阅读,一次不阅读。阅读会导致眨眼频率降低。
当鼻泪管处于水平位置时,眨眼频率与泪液引流之间存在高度相关性。每次眨眼排出的液体体积约为2微升。然而,当重力沿泪液流动方向作用于泪囊-鼻泪管中的液体时,泪液引流能力显著但变化不定地增加,眨眼频率与泪液引流能力之间无显著相关性。
年轻人的泪液引流能力受眨眼频率和重力的显著影响。泪泵功能可以通过滴液试验进行定量测量。