Suppr超能文献

用于马第三腕骨背侧平面板截骨术加压的Herbert螺钉和AO皮质骨螺钉的生物力学比较

Biomechanical comparison of the Herbert and AO cortical bone screws for compression of an equine third carpal bone dorsal plane slab osteotomy.

作者信息

Murray R C, Gaughan E M, Debowes R M, Hoskinson J J

机构信息

Centre for Equine Studies, Suffolk, England.

出版信息

Vet Surg. 1998 Jan-Feb;27(1):49-55. doi: 10.1111/j.1532-950x.1998.tb00097.x.

Abstract

OBJECTIVE

To assess feasibility of insertion of 4.5-mm Herbert cannulated bone screws (HS) using fluoroscopic guidance and compare the mechanical shear strength of these HS and 4.5-mm AO cortical bone screws (AO) for fixation of dorsal plane slab osteotomies in equine cadaver third carpal bones (C3).

ANIMALS OR SAMPLE POPULATION

Eight equine cadavers.

METHODS

Bone mineral composition and density of contralateral C3 were confirmed to be equivalent using dual-energy x-ray absorptiometry. A standard 10-mm C3 slab osteotomy was reduced using HS or AO instrumentation under fluoroscopic guidance. Specimens were loaded in shear until failure, using a materials testing apparatus.

RESULTS

HS and AO instrumentation allowed accurate reconstruction of the osteotomy, but there was difficulty encountered seating the HS proximal self-tapping threads. There was no significant difference in maximal load to failure, stiffness, or mode of failure of constructs created with the HS and AO screws.

CONCLUSIONS

Use of 4.5-mm HS for repair of C3 radial facet, dorsal plane slab fractures may result in a mechanically comparable fixation to a repair using a 4.5-mm AO. Equine dorsal C3 may be too dense, however, to allow placement of the proximal self tapping threads of the HS without potentially excessive application of torque to the screw itself.

CLINICAL RELEVANCE

Dorsal plane, radial facet slab fractures of the equine C3 are a significant clinical problem. Accurate reconstruction and stabilization are necessary for return to athletic function.

摘要

目的

评估在荧光透视引导下插入4.5毫米赫伯特空心骨螺钉(HS)的可行性,并比较这些HS螺钉和4.5毫米AO皮质骨螺钉(AO)在固定马尸体第三腕骨(C3)背侧平面板截骨术中的机械剪切强度。

动物或样本群体

八具马尸体。

方法

使用双能X线吸收法确认对侧C3的骨矿物质组成和密度相当。在荧光透视引导下,使用HS或AO器械对标准的10毫米C3板截骨术进行复位。使用材料测试设备对标本进行剪切加载直至破坏。

结果

HS和AO器械可使截骨术精确重建,但HS近端自攻螺纹的就位存在困难。HS螺钉和AO螺钉构建物的最大破坏载荷、刚度或破坏模式没有显著差异。

结论

使用4.5毫米HS修复C3桡侧小关节、背侧平面板骨折可能在机械固定方面与使用4.5毫米AO修复相当。然而,马的背侧C3可能过于致密,以至于在不向螺钉本身施加潜在过大扭矩的情况下,无法放置HS的近端自攻螺纹。

临床相关性

马C3的背侧平面、桡侧小关节板骨折是一个重要临床问题。准确重建和稳定对于恢复运动功能是必要的。