Tsuchihashi H, Katagi M, Nishikawa M, Tatsuno M
Forensic Science Laboratory of Osaka Prefectural Police H.Q., Japan.
J Anal Toxicol. 1998 Sep;22(5):383-8. doi: 10.1093/jat/22.5.383.
A human serum sample collected from a victim of the Osaka VX incident was analyzed according to our developed technique for metabolites of VX. Gas chromatography-mass spectrometry (GC-MS) in full-scan electron impact and chemical ionization modes were used, and, for more reliable confirmation, GC-MS-MS was also employed. In the serum sample, both ethyl methylphosphonic acid and 2-(diisopropylamino-ethyl)methyl sulfide were detected. These results indicated that the techniques using GC-MS and GC-MS-MS were applicable to biological samples such as serum. These results also provide the first documented, unequivocal identification of the specific metabolites of VX in victim's serum and, furthermore, clarify a part of the metabolic pathway of VX in the human body.
按照我们开发的VX代谢物分析技术,对从大阪VX事件受害者身上采集的一份人血清样本进行了分析。使用了全扫描电子轰击和化学电离模式的气相色谱-质谱联用仪(GC-MS),并且为了更可靠地进行确认,还采用了GC-MS-MS。在血清样本中,检测到了乙基甲基膦酸和2-(二异丙基氨基乙基)甲基硫醚。这些结果表明,使用GC-MS和GC-MS-MS的技术适用于血清等生物样本。这些结果还首次提供了受害者血清中VX特定代谢物的有记录的、明确的鉴定,此外,还阐明了VX在人体中的部分代谢途径。