Doyle A J, Burks R T
Department of Radiology, University of Utah, Salt Lake City 84132, USA.
J Shoulder Elbow Surg. 1998 Sep-Oct;7(5):453-7. doi: 10.1016/s1058-2746(98)90193-8.
The purpose of this study was to investigate whether the axis of the humeral articular surface bears a more constant relationship to the bicipital groove than to the distal humerus. This finding could help intraoperative placement of a shoulder prosthesis in the most anatomic position. Magnetic resonance imaging was used in 41 live volunteers and 9 cadavers to measure the distance from the biceps groove to a line drawn perpendicular to the midpoint of the humeral articular surface. A cadaver model with a plastic humeral prosthesis was used to convert this biceps distance into an angular measurement. The relationship between the biceps distance and the retroversion angle of the humeral head with respect to the humeral epicondyles was analyzed. The biceps distance averaged 11.8 mm+/-3.5 mm (equivalent to 26.8 degrees+/-8.3 degrees), whereas retroversion averaged 26.8 degrees +/-12.2 degrees. This difference in variability is significant (P=.008). Placing the fin of a humeral head implant 12 mm posterior to the biceps groove reproduces normal anatomy better than the use of an arbitrary standard of 30 degrees to 40 degrees of retroversion.
本研究的目的是调查肱骨关节面的轴线与二头肌沟的关系是否比与肱骨远端的关系更恒定。这一发现有助于在手术中以最解剖学的位置放置肩部假体。对41名活体志愿者和9具尸体使用磁共振成像来测量从二头肌沟到垂直于肱骨关节面中点所画直线的距离。使用带有塑料肱骨假体的尸体模型将该二头肌距离转换为角度测量值。分析了二头肌距离与肱骨头相对于肱骨髁的后倾角之间的关系。二头肌距离平均为11.8毫米±3.5毫米(相当于26.8度±8.3度),而后倾平均为26.8度±12.2度。这种变异性的差异具有显著性(P = 0.008)。将肱骨头植入物的鳍片放置在二头肌沟后方12毫米处比使用30度至40度后倾的任意标准能更好地重现正常解剖结构。