Garnham L, Sloper J J
Moorfields Eye Hospital, London EC1V 2PD, UK.
Br J Ophthalmol. 2006 Jan;90(1):91-5. doi: 10.1136/bjo.2005.077719.
To examine how stereoacuity changes with age as measured by a variety of stereotests.
Stereoacuity has been measured in 60 normal subjects aged 17-83 years by a single observer using TNO, Titmus, Frisby near, and Frisby-Davis distance stereotests. Motor fusion was measured at (1/3) metre and 6 metres.
Overall stereoacuity measured by all tests showed a mild decline with age (p<0.001 for all tests; Spearman rank correlation). A marked reduction to screening or absent levels of stereoacuity was seen in five subjects aged over 55, but only with the TNO stereotest. All these subjects were able to achieve a stereoacuity of 200 seconds of arc or better with the Titmus test and 340 seconds of arc or better using the Frisby near stereotest. There was a small decline with age in the base out motor fusion range measured at 6 metres (p<0.05; Spearman rank correlation). No subject described difficulty in judging distances for everyday tasks.
Although subjects showed some decline in stereoacuity with age by all tests, the large drop in stereoacuity seen in some older subjects using the TNO test was probably due to difficulty overcoming the dissociative effect of the test rather than a true reduction in cortical disparity detection. Results of random dot stereotests should be interpreted with caution in older patients, particularly with respect to their ability to perform everyday visual tasks.
通过多种立体视测试来研究立体视锐度如何随年龄变化。
由一名观察者使用TNO、Titmus、Frisby近距和Frisby - Davis远距立体视测试,对60名年龄在17 - 83岁的正常受试者进行立体视锐度测量。在1/3米和6米处测量运动融合。
所有测试所测得的总体立体视锐度均显示随年龄有轻度下降(所有测试p<0.001;Spearman等级相关性)。在5名55岁以上的受试者中,仅使用TNO立体视测试时,出现了立体视锐度显著下降至筛查水平或缺失的情况。所有这些受试者使用Titmus测试时能够达到200角秒或更好的立体视锐度,使用Frisby近距立体视测试时能达到340角秒或更好。在6米处测量的外展运动融合范围随年龄有小幅下降(p<0.05;Spearman等级相关性)。没有受试者表示在日常任务中判断距离有困难。
尽管所有测试均显示受试者的立体视锐度随年龄有所下降,但一些老年受试者使用TNO测试时出现的立体视锐度大幅下降,可能是由于难以克服该测试的分离效应,而非皮质视差检测能力的真正下降。对于老年患者,随机点立体视测试结果的解释应谨慎,尤其是关于他们执行日常视觉任务的能力方面。