非增强稳态自由进动磁共振血管成像与常规对比增强磁共振血管成像在评估胸主动脉疾病中的图像质量和诊断准确性比较。

Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic diseases.

机构信息

Cardiovascular and Thoracic Imaging, UCI Medical Center, University of California, 333 City Boulevard West, Suite 1405, Irvine, CA 92868, USA.

出版信息

Eur Radiol. 2010 Jun;20(6):1311-20. doi: 10.1007/s00330-009-1672-3. Epub 2009 Dec 16.

Abstract

OBJECTIVES

The purpose of this study was to determine the image quality and diagnostic accuracy of three-dimensional (3D) unenhanced steady state free precession (SSFP) magnetic resonance angiography (MRA) for the evaluation of thoracic aortic diseases.

METHODS

Fifty consecutive patients with known or suspected thoracic aortic disease underwent free-breathing ECG-gated unenhanced SSFP MRA with non-selective radiofrequency excitation and contrast-enhanced (CE) MRA of the thorax at 1.5 T. Two readers independently evaluated the two datasets for image quality in the aortic root, ascending aorta, aortic arch, descending aorta, and origins of supra-aortic arteries, and for abnormal findings. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were determined for both datasets. Sensitivity, specificity, and diagnostic accuracy of unenhanced SSFP MRA for the diagnosis of aortic abnormalities were determined.

RESULTS

Abnormal aortic findings, including aneurysm (n = 47), coarctation (n = 14), dissection (n = 12), aortic graft (n = 6), intramural hematoma (n = 11), mural thrombus in the aortic arch (n = 1), and penetrating aortic ulcer (n = 9), were confidently detected on both datasets. Sensitivity, specificity, and diagnostic accuracy of SSFP MRA for the detection of aortic disease were 100% with CE-MRA serving as a reference standard. Image quality of the aortic root was significantly higher on SSFP MRA (P < 0.001) with no significant difference for other aortic segments (P > 0.05). SNR and CNR values were higher for all segments on SSFP MRA (P < 0.01).

CONCLUSION

Our results suggest that free-breathing navigator-gated 3D SSFP MRA with non-selective radiofrequency excitation is a promising technique that provides high image quality and diagnostic accuracy for the assessment of thoracic aortic disease without the need for intravenous contrast material.

摘要

目的

本研究旨在评估三维(3D)非增强稳态自由进动(SSFP)磁共振血管造影(MRA)在评估胸主动脉疾病中的图像质量和诊断准确性。

方法

连续 50 例已知或疑似胸主动脉疾病的患者在 1.5T 下进行自由呼吸心电图门控非增强 SSFP MRA 和胸部对比增强(CE)MRA。两位读者分别独立评估主动脉根部、升主动脉、主动脉弓、降主动脉和主动脉弓上动脉起源处的两个数据集的图像质量和异常发现,并评估异常发现。为两个数据集确定了信噪比(SNR)和对比噪声比(CNR)。确定非增强 SSFP MRA 诊断主动脉异常的敏感性、特异性和诊断准确性。

结果

在两个数据集上均能明确检测到异常主动脉发现,包括动脉瘤(n=47)、缩窄(n=14)、夹层(n=12)、主动脉移植物(n=6)、壁内血肿(n=11)、主动脉弓壁血栓(n=1)和穿透性主动脉溃疡(n=9)。CE-MRA 作为参考标准,SSFP MRA 检测主动脉疾病的敏感性、特异性和诊断准确性均为 100%。SSFP MRA 主动脉根部的图像质量明显更高(P<0.001),而其他主动脉节段无显著差异(P>0.05)。SSFP MRA 各节段的 SNR 和 CNR 值均较高(P<0.01)。

结论

我们的研究结果表明,自由呼吸导航门控 3D SSFP MRA 采用非选择性射频激发是一种很有前途的技术,可为评估胸主动脉疾病提供高图像质量和诊断准确性,而无需静脉内造影剂。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/aebc/2861759/a611bff16148/330_2009_1672_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索