髋关节半髋关节成形术的放射立体分析--一种测量软骨磨损的高精度方法。

Radiostereometric analysis of hemiarthroplasties of the hip--a highly precise method for measurements of cartilage wear.

机构信息

Orthopaedic Department, Oslo University Hospital, 0407 Oslo, Norway.

出版信息

Osteoarthritis Cartilage. 2012 Jan;20(1):36-42. doi: 10.1016/j.joca.2011.11.006. Epub 2011 Nov 15.

Abstract

OBJECTIVE

Cartilage wear is a feature of osteoarthritis and rheumatoid arthritis. Precise measurements of wear have been difficult. Cartilage wear caused by an artificial articulating joint surface is a well-known feature of hemiarthroplasties. The aim of this study was to demonstrate that radiostereometric analysis (RSA) may be used for three-dimensional measurements of cartilage wear in hemiarthroplasties of the hip.

METHOD

We performed a phantom model study to assess the feasibility of a subsequent clinical trial. We showed that the motion of the prosthetic head relative to the pelvis was not influenced by the orientation of the prosthetic head. Twenty-two patients were randomised to treatment with a cemented or an uncemented hemiarthroplasty for an acute femoral neck fracture. Migration of the prosthetic head into the acetabulum was measured using RSA.

RESULTS

A mean migration of the prosthetic head into the acetabulum of 0.62 mm was found at 3 months [95% confidence interval (CI): 0.27-0.97] and a further migration of -0.07 mm at 12 months (95% CI: -0.16-0.32). There were no differences between the groups in prosthetic migration or functional outcome. Between three and 12 months, there was no detectable cartilage wear during the first postoperative year.

CONCLUSION

Whether the migration during the first 3 months represents a period of bedding in due to a harder opposite surface remains to be shown. RSA may be used for measurement of cartilage wear in hemiarthroplasties of the hip. This study demonstrates a highly precise method for measurements of cartilage wear.

摘要

目的

软骨磨损是骨关节炎和类风湿关节炎的特征。精确测量磨损一直很困难。人工关节表面引起的软骨磨损是半髋关节置换术的一个已知特征。本研究旨在证明放射立体测量分析(RSA)可用于髋关节半髋关节置换术的软骨磨损的三维测量。

方法

我们进行了一项模型研究,以评估随后临床试验的可行性。我们表明,假体头相对于骨盆的运动不受假体头方向的影响。将 22 名患者随机分为接受骨水泥型或非骨水泥型半髋关节置换术治疗急性股骨颈骨折。使用 RSA 测量假体头向髋臼内的迁移。

结果

在 3 个月时,发现假体头向髋臼内的平均迁移量为 0.62mm[95%置信区间(CI):0.27-0.97],在 12 个月时进一步迁移-0.07mm[95%CI:-0.16-0.32]。两组在假体迁移或功能结果方面没有差异。在 3 至 12 个月之间,在术后第一年没有检测到软骨磨损。

结论

在头 3 个月内的迁移是否代表由于对面更硬的表面而导致的磨合期仍有待证明。RSA 可用于测量髋关节半髋关节置换术的软骨磨损。本研究证明了一种高度精确的软骨磨损测量方法。