Suppr超能文献

心肺运动试验期间的脉搏传输时间和血压

Pulse transit time and blood pressure during cardiopulmonary exercise tests.

作者信息

Wibmer T, Doering K, Kropf-Sanchen C, Rüdiger S, Blanta I, Stoiber K M, Rottbauer W, Schumann C

机构信息

Department of Internal Medicine II, University Hospital of Ulm, Ulm, Germany.

出版信息

Physiol Res. 2014;63(3):287-96. doi: 10.33549/physiolres.932581. Epub 2014 Feb 24.

Abstract

Pulse transit time (PTT), the interval between ventricular electrical activity and peripheral pulse wave, is assumed to be a surrogate marker for blood pressure (BP) changes. The objective of this study was to analyze PTT and its relation to BP during cardiopulmonary exercise tests (CPET). In 20 patients (mean age 51+/-18.4 years), ECG and finger-photoplethysmography were continuously recorded during routine CPETs. PTT was calculated for each R-wave in the ECG and the steepest slope of the corresponding upstroke in the plethysmogram. For each subject, linear and non-linear regression models were used to assess the relation between PTT and upper-arm oscillometric BP in 9 predefined measuring points including measurements at rest, during exercise and during recovery. Mean systolic BP (sBP) and PTT at rest were 128 mm Hg and 366 ms respectively, 197 mm Hg and 289 ms under maximum exercise, and 128 mm Hg and 371 ms during recovery. Linear regression showed a significant, strong negative correlation between PTT and sBP. The correlation between PTT and diastolic BP was rather weak. Bland-Altman plots of sBP values estimated by the regression functions revealed slightly better limits of agreements for the non-linear model (-10.9 to 10.9 mm Hg) than for the linear model (-13.2 to 13.1 mm Hg). These results indicate that PTT is a good potential surrogate measure for sBP during exercise and could easily be implemented in CPET as an additional parameter of cardiovascular reactivity. A non-linear approach might be more effective in estimating BP than linear regression.

摘要

脉搏传输时间(PTT)是指心室电活动与外周脉搏波之间的间隔时间,被认为是血压(BP)变化的替代标志物。本研究的目的是分析心肺运动试验(CPET)期间的PTT及其与血压的关系。在20名患者(平均年龄51±18.4岁)中,在常规CPET期间连续记录心电图(ECG)和手指光电容积描记图。计算心电图中每个R波的PTT以及容积描记图中相应上升支的最陡斜率。对于每个受试者,使用线性和非线性回归模型评估PTT与上臂示波血压在9个预定义测量点之间的关系,包括静息、运动和恢复期间的测量。静息时平均收缩压(sBP)和PTT分别为128 mmHg和366 ms,最大运动时为197 mmHg和289 ms,恢复期间为128 mmHg和371 ms。线性回归显示PTT与sBP之间存在显著的强负相关。PTT与舒张压之间的相关性较弱。回归函数估计的sBP值绘制的Bland-Altman图显示,非线性模型(-10.9至10.9 mmHg)的一致性界限略优于线性模型(-13.2至13.1 mmHg)。这些结果表明,PTT是运动期间sBP的良好潜在替代指标,并且可以很容易地在CPET中作为心血管反应性的附加参数实施。非线性方法在估计血压方面可能比线性回归更有效。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验