开放式同轴介质探头有效穿透深度的测定
Open-Ended Coaxial Dielectric Probe Effective Penetration Depth Determination.
作者信息
Meaney Paul M, Gregory Andrew P, Seppälä Jan, Lahtinen Tapani
机构信息
Thayer School of Engineering at Dartmouth College, Hanover, NH 03755 USA (
Materials Division of the National Physical Laboratory in Teddington, Middlesex, UK TW11 0LW (
出版信息
IEEE Trans Microw Theory Tech. 2016 Mar;64(3):915-923. doi: 10.1109/TMTT.2016.2519027. Epub 2016 Jan 29.
We have performed a series of experiments which demonstrate the effect of open-ended coaxial diameter on the depth of penetration. We used a two layer configuration of a liquid and movable cylindrical piece of either Teflon or acrylic. The technique accurately demonstrates the depth in a sample for which a given probe diameter provides a reasonable measure of the bulk dielectric properties for a heterogeneous volume. In addition we have developed a technique for determining the effective depth for a given probe diameter size. Using a set of simulations mimicking four 50 Ω coaxial cable diameters, we demonstrate that the penetration depth in both water and saline has a clear dependence on probe diameter but is remarkably uniform over frequency and with respect to the intervening liquid permittivity. Two different 50 Ω commercial probes were similarly tested and confirm these observations. This result has significant implications to a range of dielectric measurements, most notably in the area of tissue property studies.
我们进行了一系列实验,这些实验证明了开口同轴直径对穿透深度的影响。我们使用了液体与可移动的聚四氟乙烯或丙烯酸圆柱形部件组成的两层结构。该技术能准确显示给定探头直径在样品中的深度,对于非均匀体积,该直径能合理衡量整体介电特性。此外,我们还开发了一种确定给定探头直径尺寸有效深度的技术。通过一组模拟四种50Ω同轴电缆直径的实验,我们证明在水和盐水中的穿透深度明显依赖于探头直径,但在频率范围内以及相对于中间液体的介电常数而言非常均匀。对两种不同的50Ω商用探头进行了类似测试,证实了这些观察结果。这一结果对一系列介电测量具有重要意义,尤其是在组织特性研究领域。