Prospective 5-year study with 96 short curved Fitmore™ hip stems shows a high incidence of cortical hypertrophy with no clinical relevance.

机构信息

Orthopedic Department, Kantonsspital Graubünden, Loestrasse 99, 7000, Chur, Switzerland.

Orthopedic Department, University Hospital Basel, Spitalstrasse 21, 4031, Basel, Switzerland.

出版信息

J Orthop Surg Res. 2019 May 27;14(1):156. doi: 10.1186/s13018-019-1174-1.

Abstract

BACKGROUND

An increased occurrence of cortical hypertrophy (CH) was observed 1-2 years after implanting short curved Fitmore hip stems. There are no published data about either the clinical relevance or the progression of CH over the long term.

METHODS

Ninety-six primary total hip arthroplasties were performed between 2008 and 2010 using the Fitmore hip stem. Clinical and radiological parameters were recorded preoperatively and at 1, 2, 3, and 5 year follow-up.

RESULTS

CH appeared mainly on antero-posterior radiographs in Gruen Zones 2, 3, 5, and 6. After 1 year, the diameter was 10 ± 2 mm and remained constant thereafter. The CH rate after 1 year was 69% and after 5 years 71%. Subsidence after 1 year was 1.6 ± 1.55 mm and 1.93 ± 1.72 mm after 5 years. Cortical thinning was 46% after 1 year and 56% after 5 years, mainly in Gruen Zones 7 and 8. In the first year radiolucencies were found in 51% in all Gruen Zones, and in 20% after 5 years. Patient, implant, and surgical factors did not correlate with radiological outcomes except that larger stems had more CH. After 5 years, the Harris Hip Score had improved from 59 to 94 and the Oxford Hip Score from 22 to 41. Radiographic parameters, notably CH, were not associated with clinical outcomes except that cortical thinning correlated with lower outcome scores.

CONCLUSIONS

CH correlated neither with clinical outcome nor with patient, surgical or implant factors, except for a positive correlation with stem size. The Fitmore hip stems settled within the first year to a stable fixation and then remained almost unchanged. However, cortical thinning is common in Gruen Zone 7 and 8 meaning that there is stress-shielding.

摘要

背景

在植入短曲度 Fitmore 髋关节柄后 1-2 年,观察到皮质增厚(CH)的发生率增加。目前尚无关于 CH 的长期临床相关性或进展的发表数据。

方法

2008 年至 2010 年期间,使用 Fitmore 髋关节柄进行了 96 例初次全髋关节置换术。记录术前、术后 1、2、3 和 5 年的临床和影像学参数。

结果

CH 主要出现在前后位 X 线片的 Gruen 区域 2、3、5 和 6。术后 1 年时,直径为 10±2mm,此后保持不变。术后 1 年 CH 发生率为 69%,术后 5 年为 71%。术后 1 年下沉 1.6±1.55mm,术后 5 年下沉 1.93±1.72mm。术后 1 年皮质变薄 46%,术后 5 年皮质变薄 56%,主要发生在 Gruen 区域 7 和 8。术后 1 年所有 Gruen 区域中有 51%发现放射性透亮区,术后 5 年有 20%。除了更大的柄会导致更多的 CH 外,患者、植入物和手术因素与影像学结果无关。术后 5 年,Harris 髋关节评分从 59 提高到 94,Oxford 髋关节评分从 22 提高到 41。除了皮质变薄与较低的评分结果相关外,影像学参数,尤其是 CH,与临床结果无关。

结论

CH 与临床结果、患者、手术或植入物因素均无关,除了与柄的大小呈正相关外。Fitmore 髋关节柄在第一年稳定固定后沉降,然后几乎保持不变。然而,在 Gruen 区域 7 和 8 中,皮质变薄很常见,这意味着存在应力遮挡。