锥形束计算机断层扫描诊断根管治疗后牙根纵裂:直接可视化验证的系统评价和荟萃分析。
Diagnosis of Vertical Root Fractures by Cone-beam Computed Tomography in Root-filled Teeth with Confirmation by Direct Visualization: A Systematic Review and Meta-Analysis.
机构信息
Department of Conservative Dentistry and Endodontics, Thai Moogambigai Dental College and Hospital, Dr. MGR Educational and Research Institute, Chennai, Tamil Nadu, India.
Department of Endodontology, Academic Centre for Dentistry Amsterdam, University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.
出版信息
J Endod. 2021 Aug;47(8):1198-1214. doi: 10.1016/j.joen.2021.04.022. Epub 2021 May 11.
INTRODUCTION
The purpose of this review was to determine the diagnostic accuracy of cone-beam computed tomographic (CBCT) imaging in detecting vertical root fractures (VRFs) in root-filled teeth compared with a reference standard (direct visualization).
METHODS
Electronic searches were performed in Medline, Scopus, Cochrane, and gray literature for English language articles until June 2020. Prospective and retrospective clinical studies using CBCT imaging to diagnose VRFs in root-filled teeth were included. Case reports and in vitro studies were excluded. The Quality Assessment of Diagnostic Accuracy Studies 2 tool was used to assess the risk of bias and applicability concerns. Meta-analysis was performed using Stata 16.1 software (StataCorp, College Station, TX) via the MIDAS v.3.0 package and METANDI module. Publication bias was evaluated using Deeks' funnel plot analysis. Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) was performed to evaluate the certainty of evidence. This systematic review was registered in the Open Science Framework (10.17605/OSF.IO/7JKE2).
RESULTS
Eight articles were included in this systematic review and meta-analysis. Risk of bias assessment showed that 5 articles in the patient selection domain had low risk of bias with low applicability concern. In the index test and reference standard domains, 7 articles had moderate risk of bias with moderate applicability concern. Three articles had high RB in the flow and timing domain. There was no publication bias. CBCT imaging had a pooled sensitivity and specificity of 0.78 (95% confidence interval [CI], 0.64-0.88) and 0.80 (95% CI, 0.63-0.91), respectively, and an accuracy of 0.86 (95% CI, 0.83-0.89). CBCT imaging also had pooled positive and negative likelihood ratios of 4 and 0.2, respectively. In GRADE analysis, the quality of evidence was low for sensitivity and moderate for specificity when CBCT imaging was used for the diagnosis of VRF.
CONCLUSIONS
The overall quality assessment of the included articles showed that in the patient selection domain, the risk of bias was low, and it was moderate in the index test and reference standard domains. Evidence from this systematic review and meta-analysis indicates that CBCT imaging is still not a good tool for diagnosing VRFs in root-filled teeth compared with direct visualization.
介绍
本综述的目的是确定与参考标准(直接可视化)相比,锥形束计算机断层扫描(CBCT)成像在检测根管治疗牙中的垂直根折(VRF)方面的诊断准确性。
方法
对 Medline、Scopus、Cochrane 和灰色文献中的英文文章进行电子检索,检索时间截至 2020 年 6 月。纳入使用 CBCT 成像诊断根管治疗牙中 VRF 的前瞻性和回顾性临床研究。排除病例报告和体外研究。使用诊断准确性研究质量评估 2 工具评估偏倚风险和适用性问题。使用 Stata 16.1 软件(StataCorp,德克萨斯州学院站)通过 MIDAS v.3.0 包和 METANDI 模块进行 Meta 分析。使用 Deeks 漏斗图分析评估发表偏倚。使用推荐评估、制定与评价分级(GRADE)对证据的确定性进行评估。本系统评价已在开放科学框架(10.17605/OSF.IO/7JKE2)上注册。
结果
本系统评价和 Meta 分析共纳入 8 篇文章。偏倚风险评估显示,患者选择领域的 5 篇文章具有低偏倚风险和低适用性问题。在索引测试和参考标准领域,7 篇文章具有中度偏倚风险和中度适用性问题。3 篇文章在流程和时间域具有高 RB。没有发表偏倚。CBCT 成像的敏感性和特异性的合并值分别为 0.78(95%置信区间 [CI],0.64-0.88)和 0.80(95% CI,0.63-0.91),准确性为 0.86(95% CI,0.83-0.89)。CBCT 成像的阳性和阴性似然比分别为 4 和 0.2。在 GRADE 分析中,当 CBCT 成像用于诊断 VRF 时,敏感性的证据质量为低,特异性的证据质量为中。本系统评价和 Meta 分析的证据表明,与直接可视化相比,CBCT 成像仍然不是一种检测根管治疗牙中 VRF 的好工具。