Suppr超能文献

橡皮障下覆盖修复体的光印评估:一项临床试验。

Optical impressions assessment for overlay restorations with rubber dam: A clinical trial.

机构信息

Department of Restorative Dentistry, Universitat Internacional de Catalunya, Barcelona, Spain.

Department of Restorative Dentistry, Universitat Internacional de Catalunya, Barcelona, Spain; Department of Endodontics, Universitat Internacional de Catalunya, Barcelona, Spain.

出版信息

J Dent. 2024 Apr;143:104825. doi: 10.1016/j.jdent.2023.104825. Epub 2023 Dec 28.

Abstract

OBJECTIVE

The possibility of making impressions of teeth prepared with a rubber dam in place has been proposed; however, this requires trimming and rescanning the mesh, which has been described as a cause of accuracy loss. This study aims to clinically determine whether overlay restorations obtained from a scan with a rubber dam in place have equivalent marginal fit, contact points, and occlusal fit to the same type of restorations obtained from a scan without a rubber dam.

MATERIAL AND METHODS

Thirty patients who underwent overlay restoration of a molar with at least one neighbouring tooth were selected. After tooth preparation, two scans were performed: one without a rubber dam and the other with a rubber dam. Restorations were randomly created from one scan or another. The marginal fit, interproximal contact points, and occlusal fit were evaluated clinically. Two meshes, with and without rubber dams, were also compared.

RESULTS

No significant differences were observed in the clinical evaluation of the overlays made of the two meshes. The trueness of the mesh from the impression made with a rubber dam with respect to the mesh without a rubber dam was about 40 µm in the critical areas of the preparation (margins, intaglio, and interproximal contact points).

CONCLUSIONS

The results of this study show that under the conditions performed and with the equipment used, there are no significant clinical differences between overlay restorations made from a scan with a rubber dam and those made from a scan without a rubber dam.

CLINICAL SIGNIFICANCE

Scanning with a rubber dam in place may be a valid option for certain types of restorations under certain clinical conditions.

摘要

目的

已经提出了在放置橡皮障的情况下对预备牙进行印模的可能性;然而,这需要修整和重新扫描网格,这被描述为准确性降低的原因。本研究旨在临床确定从放置橡皮障的扫描中获得的覆盖修复体是否具有与从无橡皮障扫描中获得的相同类型的覆盖修复体相当的边缘适合度、接触点和咬合适合度。

材料和方法

选择了 30 名接受磨牙覆盖修复的患者,至少有一颗邻牙。牙体预备后,进行了两次扫描:一次无橡皮障,另一次有橡皮障。从一次扫描或另一次扫描中随机制作修复体。临床评估了边缘适合度、邻面接触点和咬合适合度。还比较了有和没有橡皮障的两个网格。

结果

从有和没有橡皮障的两个网格制作的覆盖物的临床评估中没有观察到显著差异。在预备的关键区域(边缘、凹面和邻面接触点),有橡皮障印模的网格相对于无橡皮障的网格的真实度约为 40 µm。

结论

本研究的结果表明,在所进行的条件下和使用的设备下,从有橡皮障扫描中获得的覆盖修复体与从无橡皮障扫描中获得的覆盖修复体之间没有显著的临床差异。

临床意义

在某些临床条件下,放置橡皮障时扫描可能是某些类型修复体的有效选择。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验