Suppr超能文献

一种测量清醒大鼠尾袖带收缩压的简单通用方法。

A simple versatile method for measuring tail cuff systolic blood pressure in conscious rats.

作者信息

Widdop R E, Li X C

机构信息

Department of Pharmacology, Monash University, Clayton, Victoria, Australia.

出版信息

Clin Sci (Lond). 1997 Sep;93(3):191-4. doi: 10.1042/cs0930191.

Abstract
  1. The non-invasive measurement of tail cuff systolic blood pressure in conscious rats is routinely used in long-term cardiovascular studies. There are a number of commercially available tail cuff systems, however, these apparatus are generally expensive and are dedicated for single-task operations. In the present study, a simple method for measuring systolic blood pressure, which requires only minor modifications to the existing hardware found in most cardiovascular laboratories, is described. 2. Systolic blood pressure measurements were made in the conventional manner by determining the systolic blood pressure which coincided with the restoration of the caudal artery pulse. This was achieved by using an inexpensive piezo-electric pulse transducer to detect the pulse, and this was coupled to a standard data-acquisition system (MacLab, ADInstruments) normally set up to record blood pressure. This method was compared with another established tail cuff method, as well as with direct intra-arterial recordings. 3. It was found that the results obtained using both tail cuff systems were in good agreement when systolic blood pressure was measured in Wistar-Kyoto rats and spontaneously hypertensive rats. In addition, systolic blood pressure was measured over 4 weeks in 2K1C rats and sham-operated rats, with both tail cuff methods producing similar results, which were not significantly different from direct intra-arterial recordings in the same animals. 4. Thus, in the present study, with only minor modifications, the same equipment was used for both direct and indirect determinations of systolic blood pressure. This situation differs from other conventional tail cuff systems since these items are designed for a single purpose. Therefore, the current method using piezo-electric sensor/MacLab-technology should be viewed as a relatively simple, flexible and cheap alternative method to measure tail cuff systolic blood pressure in conscious rats.
摘要
  1. 清醒大鼠尾袖带收缩压的无创测量常用于长期心血管研究。市面上有多种尾袖带系统可供选择,然而,这些仪器通常价格昂贵且专为单任务操作设计。在本研究中,描述了一种测量收缩压的简单方法,该方法只需对大多数心血管实验室现有的硬件进行微小修改。2. 收缩压测量采用常规方式,通过确定与尾动脉脉搏恢复一致的收缩压来进行。这是通过使用廉价的压电脉冲传感器检测脉搏来实现的,该传感器与通常设置用于记录血压的标准数据采集系统(MacLab,ADInstruments)相连。将该方法与另一种既定的尾袖带方法以及直接动脉内记录进行了比较。3. 研究发现,在Wistar-Kyoto大鼠和自发性高血压大鼠中测量收缩压时,使用两种尾袖带系统获得的结果吻合良好。此外,对2K1C大鼠和假手术大鼠进行了为期4周的收缩压测量,两种尾袖带方法产生的结果相似,与同一动物的直接动脉内记录无显著差异。4. 因此,在本研究中,只需进行微小修改,同一设备即可用于收缩压的直接和间接测定。这种情况与其他传统尾袖带系统不同,因为那些系统是为单一目的设计的。因此,当前使用压电传感器/MacLab技术的方法应被视为一种相对简单、灵活且廉价的替代方法,用于测量清醒大鼠的尾袖带收缩压。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验