Suppr超能文献

萝卜芽和绞碎牛肉中大肠杆菌O157:H7检测方法的协同评估

Collaborative evaluation of detection methods for Escherichia coli O157:H7 from radish sprouts and ground beef.

作者信息

Onoue Y, Konuma H, Nakagawa H, Hara-Kudo Y, Fujita T, Kumagai S

机构信息

Kanagawa Prefectural Public Health Laboratory, Yokohama, Japan.

出版信息

Int J Food Microbiol. 1999 Jan 12;46(1):27-36. doi: 10.1016/s0168-1605(98)00174-3.

Abstract

For the evaluation of plating and immunological methods applicable to the detection of Escherichia coli O157:H7 from ground beef and radish sprouts, a collaborative study was conducted. It focused on a comparison of the efficiency of the plating and immunological methods using various plating agars and immuno-kits in combination with enrichment in modified E. coli broth supplemented with novobiocin (mEC + n), and using immunomagnetic separation. The plating media tested were sorbitol MacConkey agar (SMAC), SMAC supplemented with cefixime (0.05 mg/l) and potassium tellurite (2.5 mg/l) (CT-SMAC), and agars containing beta-glucuronidase substrates such as BCM O157 and CHROMagar O157. The immuno-kits used were Now E. coli, Path-Stick O157, VIP, EHEC-Tek ELISA System and Rapiblot E. coli O157. The 20 participating laboratories attempted to detect E. coli O157:H7 in 25 g chilled and frozen samples of ground beef uninoculated and inoculated with E. coli O157:H7 at levels of 138.9 and 23.9 cfu/25 g, and in 25 g chilled and frozen samples of radish sprouts uninoculated and inoculated at levels of 20.4 and 1.7 cfu/25 g. E. coli O157:H7 was recovered well from ground beef by all of the methods except direct plating with SMAC. For radish sprouts, the IMS-plating methods with CT-SMAC, BCM O157 and CHROMagar O157 were most efficient at detecting E. coli O157:H7 in more than 90% of the chilled samples inoculated at the level of 20.4 cfu/25 g. All the methods were less sensitive when applied to similar levels of E. coli O157:H7 in radish sprouts (20.4 cfu/25 g) compared with ground beef (23.9 cfu/25 g) especially if the sprouts were frozen. The sensitivity of the immuno-kits appeared to be similar to the IMS-plating methods, but the specificity was lower. Based on the results, we recommend the IMS-plating method using CT-SMAC and agars containing beta-glucuronidase substrate in combination with static enrichment incubation in mEC + n at 42 degrees C.

摘要

为评估适用于检测碎牛肉和萝卜芽中大肠杆菌O157:H7的平板计数法和免疫法,开展了一项协作研究。该研究重点比较了使用各种平板计数琼脂和免疫试剂盒,并结合添加新生霉素的改良大肠杆菌肉汤(mEC + n)进行增菌培养以及采用免疫磁珠分离法的平板计数法和免疫法的效率。所测试的平板计数培养基有山梨醇麦康凯琼脂(SMAC)、添加头孢克肟(0.05 mg/l)和亚碲酸钾(2.5 mg/l)的SMAC(CT-SMAC),以及含有β-葡萄糖醛酸酶底物的琼脂,如BCM O157和CHROMagar O157。所使用的免疫试剂盒有Now大肠杆菌、Path-Stick O157、VIP、EHEC-Tek ELISA系统和Rapiblot大肠杆菌O157。20个参与实验室尝试检测25 g冷藏和冷冻的未接种以及接种了浓度为138.9和23.9 cfu/25 g大肠杆菌O157:H7的碎牛肉样品,以及25 g冷藏和冷冻的未接种以及接种了浓度为20.4和1.7 cfu/25 g大肠杆菌O157:H7的萝卜芽样品。除了用SMAC直接平板计数外,所有方法从碎牛肉中回收大肠杆菌O157:H7的效果都很好。对于萝卜芽,采用CT-SMAC、BCM O157和CHROMagar O157的免疫磁珠分离-平板计数法在检测接种浓度为20.4 cfu/25 g的90%以上冷藏样品中的大肠杆菌O157:H7时效率最高。与碎牛肉(23.9 cfu/25 g)相比,所有方法应用于萝卜芽中相同浓度的大肠杆菌O157:H7(20.4 cfu/25 g)时敏感性较低,尤其是芽苗菜冷冻的情况下。免疫试剂盒的敏感性似乎与免疫磁珠分离-平板计数法相似,但特异性较低。基于这些结果,我们推荐采用CT-SMAC和含有β-葡萄糖醛酸酶底物的琼脂的免疫磁珠分离-平板计数法,并结合在42℃的mEC + n中进行静态增菌培养。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验