因编织涤纶人工血管扩张导致的主动脉十二指肠瘘:病例报告

Aortoduodenal fistula arising from the dilatation of a knitted Dacron graft: report of a case.

作者信息

Matsushita M, Asano Y, Kobayashi I, Tamauchi T

机构信息

Department of Surgery, Fukuroi Municipal Hospital, Shizuoka, Japan.

出版信息

Surg Today. 1999;29(5):435-8. doi: 10.1007/BF02483035.

Abstract

A fatal aortoduodenal fistula occurred in a 72-year-old man who underwent a repair of an abdominal aortic aneurysm 16 years previously with a 20 x 10 mm bifurcated knitted Dacron graft. The aortic part of his bifurcated graft had dilated to 40 mm in diameter, with a discrepancy of 20 mm in the diameter between the graft and infrarenal aorta. The fourth portion of the duodenum adhered to the left side of the anastomosis, where the aortoenteric fistula had occurred. We believe that the graft dilatation was the cause of the anastomotic failure, although other factors such as atherosclerotic degeneration of the host aorta should also be considered. Knitted Dacron grafts that have been implanted for more than 10 years should therefore be monitored carefully because they have an inherent tendency to dilate, especially those manufactured before 1981.

摘要

一名72岁男性发生了致命的主动脉十二指肠瘘,该患者16年前接受了腹主动脉瘤修复术,使用的是一枚20×10毫米的分叉编织涤纶人工血管。其分叉人工血管的主动脉部分直径已扩张至40毫米,人工血管与肾下主动脉的直径相差20毫米。十二指肠第四部分粘连于吻合口左侧,此处发生了主动脉肠瘘。我们认为人工血管扩张是吻合口失败的原因,不过也应考虑其他因素,如宿主主动脉的动脉粥样硬化退变。因此,对于植入超过10年的编织涤纶人工血管应仔细监测,因为它们有内在的扩张倾向,尤其是1981年以前生产的。