Ishida T, Ashizawa K, Engelmann R, Katsuragawa S, MacMahon H, Doi K
Kurt Rossmann Laboratories for Radiologic Image Research, University of Chicago 60637, USA.
J Digit Imaging. 1999 May;12(2):77-86. doi: 10.1007/BF03168846.
The authors developed a temporal subtraction scheme based on a nonlinear geometric warping technique to assist radiologists in the detection of interval changes in chest radiographs obtained on different occasions. The performance of the current temporal subtraction scheme is reasonably good; however, severe misregistration can occur in some cases. The authors evaluated the quality of 100 chest temporal subtraction images selected from their clinical image database. Severe misregistration was mainly attributable to initial incorrect global matching. Therefore, they attempted to improve the quality of the subtraction images by applying a new initial image matching technique to determine the global shift value between the current and the previous chest images. A cross-correlation method was employed for the initial image matching by use of blurred low-resolution chest images. Nineteen cases (40.4%) among 47 poor registered subtraction images were improved. These results show that the new initial image matching technique is very effective for improving the quality of chest temporal subtraction images, which can greatly enhance subtle changes in chest radiographs.
作者基于非线性几何变形技术开发了一种时间减法方案,以协助放射科医生检测在不同时间获得的胸部X光片中的间隔变化。当前时间减法方案的性能相当不错;然而,在某些情况下可能会出现严重的配准错误。作者评估了从其临床图像数据库中选取的100张胸部时间减法图像的质量。严重的配准错误主要归因于初始的全局匹配不正确。因此,他们试图通过应用一种新的初始图像匹配技术来确定当前胸部图像与先前胸部图像之间的全局偏移值,从而提高减法图像的质量。通过使用模糊的低分辨率胸部图像,采用互相关方法进行初始图像匹配。47张配准不佳的减法图像中有19例(40.4%)得到了改善。这些结果表明,新的初始图像匹配技术对于提高胸部时间减法图像的质量非常有效,这可以极大地增强胸部X光片中的细微变化。