Elevated galactose concentration in urine is an important clinical symptom of galactosemia and other metabolic disorders. A quantitative assay for galactose using firefly luciferase bioluminescence is presented. The assay couples the galactokinase and firefly luciferase reactions. A higher concentration of galactose present in the sample produces a faster decrease in ATP concentration, which is monitored by firefly luciferase bioluminescence. The kinetic assay is modeled and analyzed. The interference between the two reactions, the interference of certain sugars and other components in the urine, the specificity, and the optimal pH for galactokinase were studied. Calibration curves were constructed and compared with a conventional spectrophotometric assay for galactose. The bioluminescence assay is relatively fast and specific for galactose with a linear range from 1 to 20 mM galactose. The effect of other galactose metabolites (galactonate and galactitol) has also been studied.

摘要

尿中半乳糖浓度升高是半乳糖血症和其他代谢紊乱的重要临床症状。本文介绍了一种使用萤火虫荧光素酶生物发光法对半乳糖进行定量测定的方法。该测定法将半乳糖激酶反应和萤火虫荧光素酶反应偶联起来。样品中半乳糖浓度越高,ATP浓度下降越快,这通过萤火虫荧光素酶生物发光进行监测。对该动力学测定法进行了建模和分析。研究了两个反应之间的干扰、尿液中某些糖类和其他成分的干扰、特异性以及半乳糖激酶的最佳pH值。构建了校准曲线,并与传统的半乳糖分光光度测定法进行了比较。生物发光测定法相对快速且对半乳糖具有特异性,线性范围为1至20 mM半乳糖。还研究了其他半乳糖代谢产物(半乳糖酸和半乳糖醇)的影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验