Test-retest reliabilty of isokinetic hip adductor and flexor muscle strength.

作者信息

Emery C A, Maitland M E, Meeuwisse W H

机构信息

Department of Community Health Sciences, Faculty of Medicine, University of Calgary, Alberta, Canada.

出版信息

Clin J Sport Med. 1999 Apr;9(2):79-85. doi: 10.1097/00042752-199904000-00007.

Abstract

OBJECTIVE

To determine the test-retest reliability of eccentric hip flexor and adductor peak torque and endurance using a Cybex Norm isokinetic dynamometer and to evaluate muscle soreness after exercise as a result of the testing procedure.

DESIGN

Prospective test-retest reliability study.

PARTICIPANTS

A total of 19 male volunteers (21-43 years old).

INTERVENTION

Tests included hip flexor and adductor peak torque strength measured at 60 degrees/s (concentric and eccentric) and endurance measurements (total work done over 20 continuous concentric/eccentric contractions at 150 degrees/s). Subjects were tested on three occasions at 1-week intervals.

MAIN OUTCOME MEASURES

Repeated measures analysis of variance was performed for all dependent variables including the subject's dominant and nondominant side among the three test sessions. Intraclass correlation coefficients (ICCs) were calculated to compare the data between sessions. In addition, simple linear regression analysis was completed to determine the relationship between session measurements for all measures with ICC > 0.75.

RESULTS

The main findings of this study are that eccentric peak hip adductor torque was reliably measured on a Cybex Norm isokinetic dynamometer using a continuous eccentric/ concentric cycle protocol at a speed of 60 degrees/s (ICC > 0.84). Peak concentric adductor torque and peak eccentric and concentric hip flexor torque were less reliable using the same protocol (ICC < 0.67). Endurance measurements, using total work done over 20 repetitions, were not reliable for hip flexor and adductor muscle groups using a continuous eccentric/concentric cycle protocol at a speed of 150 degrees/s (ICC < 0.55). Posttest muscle soreness was found to be of significant concern with such a protocol.

CONCLUSION

The results from this test-retest reliability study confirm the reliability of eccentric peak hip adductor torque measurements for use clinically and in future research. In addition, the need to assess posttest muscle soreness after isokinetic muscle testing is confirmed.

摘要

目的

使用Cybex Norm等速测力计测定髋部偏心屈肌和内收肌的峰值扭矩及耐力的重测信度,并评估测试过程后运动引起的肌肉酸痛。

设计

前瞻性重测信度研究。

参与者

共19名男性志愿者(21 - 43岁)。

干预

测试包括以60度/秒测量髋部屈肌和内收肌的峰值扭矩强度(向心和偏心)以及耐力测量(在150度/秒下连续进行20次向心/偏心收缩所做的总功)。受试者每隔1周接受3次测试。

主要观察指标

对所有因变量进行重复测量方差分析,包括受试者在三次测试期间的优势侧和非优势侧。计算组内相关系数(ICC)以比较各测试期间的数据。此外,完成简单线性回归分析以确定ICC > 0.75的所有测量指标在各测试期间测量值之间的关系。

结果

本研究的主要发现是,使用连续偏心/向心循环方案在60度/秒的速度下,在Cybex Norm等速测力计上能可靠地测量偏心髋部内收肌峰值扭矩(ICC > 0.84)。使用相同方案时,向心内收肌峰值扭矩以及偏心和向心髋部屈肌峰值扭矩的可靠性较低(ICC < 0.67)。对于髋部屈肌和内收肌群,使用连续偏心/向心循环方案在150度/秒的速度下进行20次重复的耐力测量不可靠(ICC < 0.55)。发现采用该方案时,测试后肌肉酸痛是一个值得关注的重要问题。

结论

这项重测信度研究的结果证实了偏心髋部内收肌峰值扭矩测量在临床和未来研究中的可靠性。此外,证实了在等速肌肉测试后评估测试后肌肉酸痛的必要性。