Suppr超能文献

手术技术及使用刚性中心化装置对犬类尸体全髋关节置换术中矢状面假体柄定位及几何重建的影响。

Effect of surgical technique and use of a rigid centralizing device on stem positioning and geometric reconstruction in the sagittal plane during total hip replacement in canine cadavers.

作者信息

Schulz K S, Stover S M, Kass P H, Vasseur P B, Koehler C

机构信息

Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis 95616, USA.

出版信息

Am J Vet Res. 1999 Sep;60(9):1126-35.

Abstract

OBJECTIVE

To determine the effect of surgical technique and use of a rigid centralizing device on stem positioning and geometric reconstruction in the sagittal plane during total hip replacement in dogs.

SAMPLE POPULATION

Bilateral femurs from 8 adult mixed-breed canine cadavers.

PROCEDURE

Femurs were prepared for femoral stem implantation, using 4 variations in technique. Proximal femoral reconstruction and femoral stem positioning were evaluated on radiographs.

RESULTS

Implants evaluated in this study accurately reconstructed displacement of the femoral head of the intact canine femur in the sagittal plane. Centralization of the distal aspect of the stem was optimized by use of an undersized femoral stem. Ostectomy at the level of the lesser trochanter resulted in the smallest diaphysis-to-implant angle. Anteversion and retroversion of implants significantly decreased the distance between the distal tip of the implant and the adjacent cortex, compared with normoversion. The centralizing device significantly increased the minimum distance between the distal tip of the implant and adjacent cortex but did not improve the odds of actually centralizing the tip of the implant.

CONCLUSIONS AND CLINICAL RELEVANCE

Malpositioning of implants in the sagittal plane may be minimized through ostectomy at the lesser trochanter and use of an undersized implant positioned in normoversion. Use of a polymethylmethacrylate centralizing device will help eliminate contact between the implant tip and adjacent cortex. Implantation of an undersized femoral component, avoidance of substantial anteversion or retroversion, and use of a rigid centralizing device are recommended when using the prosthesis described-for total hip replacement of dogs.

摘要

目的

确定手术技术及使用刚性中心化装置对犬全髋关节置换术中矢状面假体柄定位及几何重建的影响。

样本群体

8只成年杂种犬尸体的双侧股骨。

方法

采用4种不同技术为股骨柄植入准备股骨。通过X线片评估股骨近端重建及股骨柄定位情况。

结果

本研究评估的植入物准确重建了完整犬股骨在矢状面的股骨头移位情况。使用尺寸较小的股骨柄可优化柄远端的中心化。小转子水平截骨导致骨干与植入物之间的角度最小。与正常旋转相比,植入物的前旋和后旋显著减小了植入物远端尖端与相邻皮质之间的距离。中心化装置显著增加了植入物远端尖端与相邻皮质之间的最小距离,但并未提高植入物尖端实际中心化的几率。

结论及临床意义

通过小转子截骨及使用尺寸较小且正常旋转定位的植入物,可将矢状面植入物位置不当的情况降至最低。使用聚甲基丙烯酸甲酯中心化装置有助于消除植入物尖端与相邻皮质之间的接触。在使用所述假体进行犬全髋关节置换时,建议植入尺寸较小的股骨部件,避免过度前旋或后旋,并使用刚性中心化装置。