Glukhovskiy P, Landers T A, Vigh G
Chemistry Department, Texas A&M University, College Station 77842-3012, USA.
Electrophoresis. 2000 Mar;21(4):762-6. doi: 10.1002/(SICI)1522-2683(20000301)21:4<762::AID-ELPS762>3.0.CO;2-Y.
The IsoPrime multicompartment electrolyzer, equipped with a series of isoelectric membranes with closely spaced pI values, was used for the first time for the preparative-scale separation of the enantiomers of dansyl phenylalanine with hydroxypropyl beta-cyclodextrin as resolving agent. The final separation conditions could be established easily in three successive experiments by rationally narrowing the pH steps between the neighboring isoelectric membranes. The final separation yielded products with an enantiomeric excess greater than 99.9%, at production rates of about 0.1 mg/h. The greatest experimental difficulty was caused by the relatively high salt content of the hydroxypropyl beta-cyclodextrin used, which resulted in high conductivity and limited the maximum field strength one could use.
配备了一系列等电点值紧密间隔的等电膜的IsoPrime多隔室电解槽,首次用于以羟丙基-β-环糊精为拆分剂对丹磺酰苯丙氨酸对映体进行制备规模的分离。通过合理缩小相邻等电膜之间的pH步长,在三个连续的实验中可以轻松确定最终的分离条件。最终分离得到的产物对映体过量大于99.9%,产率约为0.1 mg/h。最大的实验困难是所用羟丙基-β-环糊精的盐含量相对较高,这导致电导率高,并限制了可使用的最大场强。