Suppr超能文献

多链接ª支架在猪模型中的实验结果。

Experimental Results with the Multi-Linkª Stent in a Porcine Model.

作者信息

Thomas WJ, Laird JR, Bailey L, Hoopes TG, Hillhouse R, Scott D, Jones R, Virmani R, Carter AJ

机构信息

Associate Director, Cardiovascular Research, Heart Institute at Borgess Medical Center, 1521 Gull Road, Kalamazoo, MI, 49001, USA.

出版信息

J Invasive Cardiol. 1997 Sep;9(7):453-460.

Abstract

OBJECTIVES

The purpose of this study was to assess the delivery characteristics and the vascular response to placement of the Multi-Linkª stent in normal porcine coronary arteries. BACKGROUND: The Multi-Link stent is a balloon expandable stainless steel stent with an interconnected corrugated ring structure designed to provide a high degree of compressive resistance while preserving longitudinal flexibility. The placement characteristics and vascular response to this stent in normal porcine coronary arteries has not been characterized. METHODS: We tested the delivery characteristics and vascular response to the Multi-Link stent in 19 normolipemic miniature swine. Quantitative coronary angiography was used to define stent performance characteristics such as stent expansion and recoil. Histologic assessment of the stented arteries was used to evaluate the acute and chronic vascular response to stent placement. RESULTS: Thirty-five of thirty-five stents (100%) were successfully implanted in the left anterior descending (n = 14), left circumflex (n = 8) or right (n = 13) coronary arteries of nineteen swine. The baseline angiographic mean lumen diameter of the stented coronary segment was 3.41 +/- 0.32 mm and increased to 3.53 +/- 0.33 mm (p < 0.001) after stent placement. The balloon inflated stent diameter was 3.61 +/- 0.36 mm with minimal recoil to a final minimal lumen diameter of 3.53 +/- 0.33 mm after implant (p = 0.001). Linear regression analysis revealed that the percent stent recoil had a significant positive correlation with the stent to artery ratio or the degree of stent over-sizing (r = 0.67; p < 0.0001). Angiographic and histologic follow-up at 72 hours (n = 9), 14 days (n = 12) and 56 days (n = 12) demonstrated that all stents were patent without evidence of migration, intraluminal filling defect or side-branch occlusion. On histology, there was rare evidence of stent-induced deep arterial wall injury such as rupture of the internal elastic lamina and medial laceration. There was no significant difference in the mean injury score observed on day 3 (0.23 +/- 0.22), 14 (0.35 +/- 0.28) or 56 (0.36 +/- 0.27) after implant (p = 0.27). On day 3, the mean thrombus thickness overlying the stent wires was 70 +/- 98µ. The mean neointimal area was similar at 14 and 56 days after implant (1.63 +/- 1.25 mm2 versus 1.78 +/- 0.68 mm2, p = 0.54). CONCLUSIONS: The MULTI-LINK stent easily tracked the coronary arteries and deployed reliably in this experimental model. The multiple interconnected ring geometry of the stent provides adequate compressive resistance, longitudinal flexibility and uniform coverage of the arterial wall throughout the length of the endoprothesis. The stent has acceptable blood and tissue biocompatibility in normal porcine coronary arteries. Oversizing this stent (>10 percent) may have a theoretical disadvantage resulting in a proportionally higher degree of stent recoil. The results of clinical trials will determine if the design features of the Multi-Link stent favorably impact on procedural outcome or long-term patency.

摘要

目的

本研究旨在评估Multi-Linkª支架在正常猪冠状动脉中的输送特性及血管反应。背景:Multi-Link支架是一种球囊扩张式不锈钢支架,具有相互连接的波纹环结构,旨在提供高度的抗压性,同时保持纵向柔韧性。该支架在正常猪冠状动脉中的放置特性及血管反应尚未得到描述。方法:我们在19只血脂正常的小型猪中测试了Multi-Link支架的输送特性及血管反应。采用定量冠状动脉造影来确定支架的性能特征,如支架扩张和回缩情况。对置入支架的动脉进行组织学评估,以评价支架置入后的急性和慢性血管反应。结果:35个支架中的35个(100%)成功植入19只猪的左前降支(n = 14)、左旋支(n = 8)或右冠状动脉(n = 13)。置入支架的冠状动脉节段的基线血管造影平均管腔直径为3.41±0.32 mm,置入支架后增加至3.53±0.33 mm(p < 0.001)。球囊膨胀后支架直径为3.61±0.36 mm,植入后回缩最小,最终最小管腔直径为3.53±0.33 mm(p = 0.001)。线性回归分析显示,支架回缩百分比与支架与动脉比值或支架超大尺寸程度呈显著正相关(r = 0.67;p < 0.0001)。在72小时(n = 9)、14天(n = 12)和56天(n = 12)进行的血管造影和组织学随访表明,所有支架均通畅,无移位、管腔内充盈缺损或分支闭塞的证据。组织学检查显示,罕见支架引起的动脉壁深层损伤证据,如内弹力层破裂和中层撕裂。植入后第3天(0.23±0.22)、第14天(0.35±0.28)或第56天(0.36±0.27)观察到的平均损伤评分无显著差异(p = 0.27)。在第3天,覆盖支架金属丝的平均血栓厚度为70±98µ。植入后第14天和第56天的平均新生内膜面积相似(1.63±1.25 mm²对1.78±0.68 mm²,p = 0.54)。结论:在该实验模型中,MULTI-LINK支架易于跟踪冠状动脉并可靠地展开。支架的多个相互连接的环几何结构提供了足够的抗压性、纵向柔韧性以及在内假体全长范围内对动脉壁的均匀覆盖。该支架在正常猪冠状动脉中具有可接受的血液和组织生物相容性。使该支架超大尺寸(>10%)可能在理论上存在劣势,导致支架回缩程度相应更高。临床试验结果将确定Multi-Link支架的设计特点是否对手术结果或长期通畅性产生有利影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验