Suppr超能文献

通过无鞘接口与质谱仪联用的毛细管电泳条件优化。

Optimization of capillary electrophoresis conditions for coupling to a mass spectrometer via a sheathless interface.

作者信息

Samskog J, Wetterhall M, Jacobsson S, Markides K

机构信息

Department of Analytical Chemistry, Uppsala University, Sweden.

出版信息

J Mass Spectrom. 2000 Jul;35(7):919-24. doi: 10.1002/1096-9888(200007)35:7<919::AID-JMS20>3.0.CO;2-N.

Abstract

When optimizing a capillary electrophoresis/electrospray ionization mass spectrometry (CE/ESI-MS) system, consideration has to be given not only to the separation but also to the electrospray stability. Methods developed for CE/UV analysis of drugs and peptides were considered and modified to be suitable for a CE/MS system with a robust sheathless interface. Different concentrations of the organic modifiers acetonitrile, methanol and 2-propanol were used in the separation buffer. The type and concentrations of these modifiers were also compared with reference to electrospray stability, sensitivity and time of analysis. In addition, different ionic strengths in the buffers were evaluated with reference to electrospray stability. The repeatability was used for the estimation of electrospray stability. The degree to which these parameters influenced the separation and the ESI stability was studied using a nine-peptide standard mixture and the antibiotic drugs bacampicillin and ampicillin as test substances. The analysis time and resolution were used as measures of the efficiency of the separation. A time-of-flight MS analyzer was used since it has the potential advantages of becoming a better fit for integration of CE with MS owing to the speed and sensitivity of this mass analyzer. The detection limit, i.e. 1 microM, for bacampicillin was comparable to what could be achieved with CE/MS on a quadrupole instrument using selected ion monitoring and sheath flow ESI.

摘要

在优化毛细管电泳/电喷雾电离质谱(CE/ESI-MS)系统时,不仅要考虑分离效果,还要考虑电喷雾稳定性。对已开发的用于药物和肽的CE/UV分析方法进行了评估和修改,使其适用于具有坚固无鞘接口的CE/MS系统。在分离缓冲液中使用了不同浓度的有机改性剂乙腈、甲醇和2-丙醇。还参照电喷雾稳定性、灵敏度和分析时间,对这些改性剂的类型和浓度进行了比较。此外,参照电喷雾稳定性评估了缓冲液中的不同离子强度。用重复性来评估电喷雾稳定性。以九肽标准混合物以及抗生素药物巴卡西林和氨苄西林作为测试物质,研究了这些参数对分离和电喷雾电离(ESI)稳定性的影响程度。分析时间和分离度用作分离效率的衡量指标。使用飞行时间质谱仪,因为由于这种质谱仪的速度和灵敏度,它有可能更适合CE与MS的联用。巴卡西林的检测限为1 microM,与使用选择离子监测和鞘流ESI的四极杆仪器上的CE/MS所能达到的检测限相当。

相似文献

1
Optimization of capillary electrophoresis conditions for coupling to a mass spectrometer via a sheathless interface.
J Mass Spectrom. 2000 Jul;35(7):919-24. doi: 10.1002/1096-9888(200007)35:7<919::AID-JMS20>3.0.CO;2-N.
3
Recent advances in sheathless interfacing of capillary electrophoresis and electrospray ionization mass spectrometry.
J Chromatogr A. 2007 Aug 3;1159(1-2):2-13. doi: 10.1016/j.chroma.2007.03.115. Epub 2007 Apr 4.
4
Design of a sheathless capillary eletrophoresis-mass spectrometry probe for operation with a Z-spray ionization source.
Electrophoresis. 2000 Apr;21(7):1354-62. doi: 10.1002/(SICI)1522-2683(20000401)21:7<1354::AID-ELPS1354>3.0.CO;2-Q.
5
Simplifying CE-MS operation. 2. Interfacing low-flow separation techniques to mass spectrometry using a porous tip.
Anal Chem. 2007 Jun 1;79(11):4241-6. doi: 10.1021/ac0704560. Epub 2007 Apr 21.
7
A robust approach for the analysis of peptides in the low femtomole range by capillary electrophoresis-tandem mass spectrometry.
Electrophoresis. 2002 Sep;23(18):3149-59. doi: 10.1002/1522-2683(200209)23:18<3149::AID-ELPS3149>3.0.CO;2-8.
8
Fraction collection in capillary electrophoresis for various stand-alone mass spectrometers.
J Chromatogr A. 2009 Apr 24;1216(17):3666-73. doi: 10.1016/j.chroma.2008.12.061. Epub 2008 Dec 27.
10
Capillary electrophoresis-mass spectrometry for impurity profiling of basic pharmaceuticals using non-volatile background electrolytes.
J Chromatogr A. 2007 Aug 3;1159(1-2):175-84. doi: 10.1016/j.chroma.2007.05.070. Epub 2007 May 29.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验