[In vivo study of kinematics of the elbow using electromagnetic goniometer].

作者信息

Chantelot C, Fontaine C, Diop A, Migaud H, Lavaste F, Duquennoy A

机构信息

Service d'Orthopédie B, Hôpital Roger Salengro, CHRU de Lille.

出版信息

Ann Chir Main Memb Super. 1998;17(1):68-77. doi: 10.1016/s0753-9053(98)80023-9.

Abstract

We used an electromagnetic goniometer to study the angular and translations displacements between the humerus and the 2 bones of the forearm. The electromagnetic gionometer allows acquisition of the coordinates and analysis of the 6 degrees of motion. To validate our external fixation apparatus, we used a fresh body upper limb. At first, a series of measurements was conducted with the apparatus. We then performed a series of measurements, by fixing the transmitter and receiver with external fixation pins directly inserted into the bones of the arm and forearm. To assess the reproducibility of our method, we chose a healthy subject. We performed 20 measurements over his right and left elbows. In order to study normal elbow kinematics, we performed measurements on 10 healthy subjects. The study of rotation showed that the apparatus was adapted to measure flexion-extension. It limited pronation-supination movement to about 26.7 degrees. Abduction was increased by 19.7 degrees by our apparatus during flexion-extension, but abduction was reliable within a 2 degrees range for pronation-supination. The sliding movements recorded during flexion-extension were reliable within approximately 3 mm for frontal translations, 6 mm for fitting, and 1 mm for external translations. For the sliding movements recorded in pronation-supination, frontal translations were reliable within about 7 mm, fitting was reliable within 1.9 mm and external translations were reliable within about 2.9 mm. During flexion-extension of the elbow, flexion-extension, frontal translations and external translations were reproducible. The reproducibility test showed that only 6 measurements were reproducible. The kinematic elbow study of a healthy subject showed that the average amplitude of flexion-extension was close to the measurement observed with the manual goniometer. The results in the healthy subject showed that the elbow is more stable during pronation-supination than during flexion-extension. This preliminary study should allow us, in the near future, to study elbow prosthesis kinematics.

摘要

我们使用电磁测角仪来研究肱骨与前臂两块骨头之间的角位移和平移位移。电磁测角仪能够获取坐标并分析六个运动自由度。为了验证我们的外固定装置,我们使用了一具新鲜尸体的上肢。首先,使用该装置进行了一系列测量。然后,通过将发射器和接收器用直接插入手臂和前臂骨头的外固定针固定,我们又进行了一系列测量。为了评估我们方法的可重复性,我们选择了一名健康受试者。我们对他的左右肘部进行了20次测量。为了研究正常的肘部运动学,我们对10名健康受试者进行了测量。旋转研究表明该装置适用于测量屈伸。它将旋前 - 旋后运动限制在约26.7度。在屈伸过程中,我们的装置使外展增加了19.7度,但对于旋前 - 旋后,外展在2度范围内是可靠的。在屈伸过程中记录的滑动运动,额状面平移在约3毫米内可靠,拟合在6毫米内可靠,外侧平移在1毫米内可靠。对于旋前 - 旋后记录的滑动运动,额状面平移在约7毫米内可靠,拟合在1.9毫米内可靠,外侧平移在约2.9毫米内可靠。在肘部屈伸过程中,屈伸、额状面平移和外侧平移是可重复的。可重复性测试表明只有6次测量是可重复的。一名健康受试者的肘部运动学研究表明,屈伸的平均幅度接近用手动测角仪观察到的测量值。健康受试者的结果表明,肘部在旋前 - 旋后期间比在屈伸期间更稳定。这项初步研究应使我们在不久的将来能够研究肘部假体的运动学。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验